WALL-WALL DOUBLE-CIRCUIT GAS BOILER WITH CLOSED COMBUSTION CHAMBER
USER GUIDE
WELLER
Mars 26

Content


  • Design and names of parts 3

  • Inputs/outputs 3

  • 4

  • Safety Notes 5

  • 6

  • Instructions for using the control panel 7

  • Description of fault codes 7

  • Unpacking box 8

  • Packing List 8

  • Installation illustrations 9

  • Boiler installation 9

  • Description connecting elements 11

  • Water supply, refilling and draining 13

  • Ignition adjustment 14

  • User operation 14

  • Security system 16

  • Maintenance 17

  • Warranty 18

  • Warranty card 19

Design and names of parts

1

. Fan

2. Main heat exchanger

3. Temperature limiter control

4. Flame ignition/ionization electrode

5. Burner

6. Flow sensor

7. Gas valve

8. DHW temperature sensor

9. Three way valve

10. Pressure sensor microswitch

three way valve

11. Heating circuit temperature sensor

12. Fan operation sensor

13. Expansion tank

14. Automatic release valve

1


5. Safety valve

16. Secondary heat exchanger

17. Water pump

18. Water pressure gauge

19. Control panel display board

20. Control panel board

Inputs/outputs

A water outlet for heating

C output hot water

G gas inlet

F cold water inlet

R water inlet for heating
Basic specifications


  • Digital display of heating circuit / DHW temperature

  • Automatic fault detection function and fault code display

  • Proportional continuous flame control, the flame is adjusted according to changes in heat input to perform automatic regulation to ensure constant heating/hot water temperature.

  • If the flame fails, the flame failure protection is activated, which instantly cuts off the gas supply.

  • The boiler has two independent heat exchangers for heating and domestic hot water.

  • Temperature limit protection. Prevents damage to the boiler due to excessive temperature rise.

  • With a sharp increase in pressure in the heating system, automatic valve bypass protects the heat exchanger from overheating.

  • Protection using a 3 bar safety valve (1 bar = 1 kgf/cm2 = 0.1 MPa) protects the system pipeline from excess pressure.

  • If there is no draft in the chimney, the pressure switch automatically turns off the boiler.

  • The water pressure switch ensures that the boiler will not start if there is no water or its pressure is insufficient.

  • Three minute delay function. Used to prevent frequent boiler starts and increases its service life.

  • Blocking protection circulation pump: The system automatically turns on the pump once a day for 1 minute.
Safety Notes

▲ The boiler is intended only for heating water for heating and DHW systems.

▲ If the boiler is not working, turn off the gas supply and power supply. Contact an authorized technician for service.

▲ Power supply required for normal operation boiler – 220~230 W/50 Hz alternating current. The manufacturer and seller are not responsible for damage caused by using a different power source.

▲ In frosty weather, the boiler must be supplied with electricity and gas to prevent the water from freezing and blocking the pipes.

▲ Make sure that the water pressure in the heating system is at least 0.5 bar, or add water to the boiler according to the method used.

▲ Make sure that the type of gas used matches the type of gas indicated on the nameplate gas boiler.

▲ If the boiler is not in use for a long period of time, close the gas supply, disconnect the power supply and drain the boiler and pipes.

▲ Before cleaning the boiler, turn off the power supply.

▲ Do not use electrical equipment if you smell gas. Immediately open the window and close the gas valve, and then call a service technician by telephone.

▲ Do not use near gas cylinders, gas and other flammable materials. Do not place flammable materials such as plastic, paper or fabric on the gas boiler.

▲ Do not pull, twist, or cut the power cord.

▲ Do not place foreign objects on the exhaust air outlet or air inlet to avoid blockage or fire.

Basic technical specifications


Model

Mars 26

Mars 32

Unit change

Nominal heat input

26

32

kW

Nominal thermal power

24

29,5

kW

Heating system temperature range

30~80

30~80

°C

Operating pressure heating systems

0.5~1.5

0.5~1.5

bar

Maximum pressure heating systems

3

3

bar

Expansion tank capacity

6

8

l

Expansion tank set pressure

1

1

bar

Hot water temperature adjustment

30~60

30~60

°C

Maximum pressure tap water

6

6

bar

Minimum tap water pressure

0,2

0,2

bar

△t=25°C, possibility of obtaining hot water

13

15

l/min

△t=35°C, possibility of obtaining hot water

9,5

10,7

l/min

Voltage/frequency

220~230/50

220~230/50

V/Hz

Maximum power consumption

110

150

W

Insulation class

I

I

Pipe connection

Connecting water pipes for heating

G3/4

G3/4

Gas inlet

G3/4

G3/4

Connecting water pipes for shower

G1/2

G1/2

Air inlet/outlet

60/100

60/100

mm

Nominal pressure for natural gas

0,02

0,02

bar

Nominal pressure for LPG

0,03

0,03

bar

Net weight

38,5

39

kg

dimensions: L×W×H

740 × 410 × 328

740 × 410 × 328

mm

Instructions for using the control panel


1

display

Shows temperature and all types of codes.

2

Increasing the water temperature for the heating system



3

Reducing the water temperature for the heating system



4

Increasing the water temperature for DHW

Press once, the set temperature value will increase by 1 degree.

5

Reducing the water temperature for DHW

Press once, the set temperature value will decrease by 1 degree.

6

Winter/summer switch

Selects the boiler operating mode

7

Reset

Locks automatically, restart the boiler

8

On off

Starting and stopping the boiler

9

Water pressure gauge

Shows water pressure in the heating system

Description of fault codes

Unpacking the box

The boiler is packed in a rigid box, and cushioning foam is placed in the box to ensure the safety of the product and the absence of damage during transportation. To remove the boiler from the box, follow the steps in accordance with the following pictures:

1. First cut the strapping of the packaging box (Fig. 1)

2. Unfold the box as shown in Figure 2.

3. Separately take out the foam and packaging accessories; do not damage the devices (Fig. 3)

4. Take the boiler and remove the bottom foam pad (Fig. 4)

^ Attention: Do not handle the plastic control unit with your hands when unpacking the stake.
Packing list

Unfold the box and check the following list of accessories:

Installation illustrations



Boiler installation

Installation Safety Precautions


  • Installation, maintenance, installation, repair and instruction of the owner must be carried out by a specialist from the operating organization of the gas industry or a specialist from an organization licensed for this type of activity.

  • Securely mount the boiler to a wall made of non-combustible material.

  • Do not place flammable or explosive materials near the boiler.

  • It is prohibited to install the boiler on other gas devices.

  • It is prohibited to install the boiler in a bedroom, living room or basement.

  • It is prohibited to install the boiler near stairs and emergency exits (minimum distance 5 meters).

  • There should be no wires above the boiler installation site, electrical devices and gas pipes.

  • The boiler outlet should be located near the ventilation.

  • You should use a special plug socket which must be grounded.

  • It is necessary to maintain the supply voltage within 220 V~230 V, for this it is recommended to install a voltage stabilizer.

  • The boiler is installed in a vertical position.

  • Install the drain valve in the lowest position of the heating system.

  • Install a filter on the heating water return pipe.

  • Be sure to flush the pipes or add an anti-scaling agent when introducing water into the heating system.

  • Thoroughly flush the entire heating system.

  • All pipes must be connected tightly to avoid leaks and other undesirable phenomena in the pipeline.

  • If it is necessary to carry out work on the boiler, do not put foreign objects into it to avoid disrupting the normal operation of the boiler.
^

Mounting panel installation

D


For installation and more convenient Maintenance a suspended panel is used. Before installing the boiler, first use suspended panel to determine the mounting position, and then drill two holes in the selected position. Pull out the expansion bolt on the wall to secure the panel. Finally, adjust the level and height between the panel and the floor, which should be at least 1.95 m.
^ Drilling holes for the flue
P

After installing the panel, drill holes in the wall for the flue according to the picture. The diameter of the holes is 110 mm, the outlet part of the pipe must have a slope of at least 3% to ensure the flow of condensation water.

^ Hanging the boiler

Attach the boiler to the panel and make sure it is securely installed.

(As shown in the picture on the right).
Note: The following must be ensured around the boiler

minimum free space.

^ To the side surfaces at least 200 mm;

At least 450 mm to the top surface;

At least 300 mm to the bottom surface;

At least 500 mm to the front surface.


^ Flue installation
Restrictive air ring

Refer to the following table when installing all models, whether the air restrictor ring is installed or not.

When installing a flue maximum length pipes cannot exceed 3 meters. When adding a 135° elbow, the pipe length will be reduced by 0.5 m; when adding a 90° elbow, the pipe length will be reduced by 1 m. Two parts of a 90° elbow cannot be installed (except for the elbow between the flue and the exhaust duct).


  • Attention:
1. The gas duct must be sealed. The pipe material must be resistant to deformation, heat and must prevent fire and condensation.

^ 2. The flue connection must be sealed. The material of the sealed connection must be resistant to heat and corrosion.

3. The flue should have a slope of 2~3 degrees behind the wall to ensure that condensation water flows out.

^ 4. Do not use material that promotes condensation to fill the space between the pipe and the hole. The pipe should be easy to remove.

5. The pipe must be connected from the outside. It is forbidden to start the boiler without an installed pipe.

6


. For distances between the pipe outlet and surrounding walls, see the figure below.

mm

Pipe connection

^ Gas pipe connection

A gas valve must be installed at the connection between the flue pipe and the gas inlet.

The gas duct must be clean. If there are impurities in the gas, a filter must be installed at the gas inlet.

Do not use the flue as an equipment grounding line.

1


. heating water inlet

2. hot water outlet

3. cold water inlet

4. circulating heating water

5.gas inlet

Wiring diagram


Water supply, replenishment and drainage
Water supply


  1. Unscrew the automatic faucet release valve completely.

  2. Open the heating system valve and the outlet valve at the end of the equipment.


  3. Insert the protective insert and apply power, then start the boiler (Do not open the gas switch).


  4. Start the boiler again and again to restart the circulation pump to remove any residual air.

  5. Water pressure in heating system will decrease after releasing air .

  6. Close the boiler and turn off the power.

  7. Close the outlet valve at the end of the heating system equipment.

Replenishment

E If, after operating the boiler for some time, the water pressure in the heating system has decreased due to the filling of the pipe system, then in order to prevent abnormal operation of the boiler due to low pressure water, water should be added to the boiler when the pressure drops below 0.5 bar.


  1. Make sure the outlet valve on the pump is open

  2. Rotate the handle counterclockwise to open the water supply valve.

  3. Check the pressure using the water pressure gauge on the control panel. When the reading reaches 1-1.2 bar, close the water supply valve by turning clockwise.

  4. Z
    water

    refill valve
    Run the boiler again and again to restart the circulation pump to remove residual air.


  5. D
    reducer for safety valve
    The water pressure in the heating system will decrease after bleeding . Repeat operations (3), (4), (5) until the pressure is between 1-1.2 bar.

Draining the system

Drying the heating system


  1. Turn off the boiler and disconnect the power supply.

  2. Open the boiler and all valves on the heating system piping.

  3. Open the drain valve and release water from the system, then close the drain valve.

Draining the DHW system


  1. Disconnect the water inlet pipe from the boiler.

  2. Open the heating water pipe valve and release the water.

  • Attention:

When draining the system, close the boiler and turn off the power supply.

^ The safety valve drain must be connected directly to drainage system, it is not allowed to install valves in the middle of the connecting pipe.

After draining and supplying water is completed, it is necessary to close the drain valve and the water supply valve.
^ Ignition adjustment

Checks before starting work


    1. Check all heating system and domestic hot water connections to ensure there are no water leaks.

    2. Check whether the automatic boiler outlet valve is open.

    3. Make sure that the heating system pressure is between 1-1.2 bar.

    4. Make sure that the gas used matches the gas specified on the nameplate.

Adjustment

^ Attention: (1) Adjustment must be performed by qualified personnel.

(2) If there are problems with heating and water quality caused by the heating system and domestic hot water, please contact the authorized service center.

User operation

in winter

Heating operation


▲ Attention: The heating water outlet temperature can be set within 30~80°C. If you have chosen low-temperature floor heating, the adjustment must be carried out by qualified specialists from an official service center. The heating water outlet temperature can be set within 30~55°C.
^ Turning on water heating for DHW


  1. After setting the temperature, this setting will be saved automatically. The display will return to the current heating system water temperature and the boiler will operate in winter heating mode.

  1. Open the tap, the boiler will automatically switch from heating mode to DHW heating mode. When the boiler is operating in shower water heating mode, close the tap and the boiler will switch from DHW heating mode to heating mode.

Summer mode (Shower water heating function only)


  1. After setting the temperature, this setting will be saved automatically. The display will return to indicating the current water temperature of the heating system and the boiler will operate in summer heating mode

  2. Open the tap, the boiler will turn on and operate in DHW mode. Close the tap, the boiler will close and go into standby mode.
^ Attention: (1) If the unit stops working for a short time, you should check that the power supply is normal to prevent the fan from stopping.

(2) Make sure that the power supply and gas supply are normal to ensure defrosting function in cold weather.

(3) When stopping the unit for a long time, close the gas pipe valve, turn off the power, and drain the water from the system.

Security system

The boiler uses a security code indication system. If the boiler enters protection mode, determine the fault according to the following codes:

^ Low water protection

E 1

When the display shows the code shown in the figure on the right, this means that the boiler is entering protection mode due to insufficient water. Switch off the boiler and then supply water according to the water supply method described on page 6. When the water pressure reaches 1-1.2 bar, try turning on the power again and starting the boiler.

^ Ignition fault protection or overheating protection

E 2

When the display shows the code shown in the figure on the right, this means that the boiler is entering protection mode due to an ignition fault or the heating system water temperature is rapidly rising and reaches 95°C. Check whether gas is supplied and whether the gas pipe valve is open. Try turning on the power again and press the "○" button, then press the "reset" button to ensure that the boiler operates in normal gas supply mode.

^ Heating system sensor fault protection

E 3

due to abnormal operation of the heating system water sensor. First turn off the boiler and then contact qualified personnel authorized by our company.
Protection against DHW sensor failure

When the display shows the code shown in the figure on the right, this means that the boiler is entering protection mode and ^

E 4

due to abnormal operation of the G sensor

E 4

Sun. First turn off the boiler and then contact qualified personnel authorized by our company.

^P

E 5

software error

When the display shows the code shown in the figure on the right, it means that a software error has occurred. You just need to press the reset button or restart the boiler. If the control board failure continues, please contact qualified personnel authorized by our company.

^ Exhaust system fault protection

When the display shows the code shown in the figure on the right, this means that the boiler is entering protection mode and

E 6

due to abnormal operation of the exhaust system. This is a temporary situation. When the exhaust system works normally, the boiler will start automatically. If the boiler does not start automatically, contact qualified personnel authorized by our company.
^ overheat protection

E 7

When the display shows the code shown in the figure on the right, this means that the boiler is entering a protection mode caused by a rapid increase in the heating system temperature to 95°C or a rapid increase in the DHW temperature to 80°C. When the temperature drops to a value 6°C less than the set temperature, press the "reset" button to start the boiler.
Maintenance


  • Check for leaks water pipes and replace the O-ring and easily damaged material.

  • The system pressure should be 1-1.2 bar, otherwise, supply water according to the water supply method described on page 6.

  • Check for leaks gas pipes and replace the O-ring and easily damaged material.

  • Check the burner and main heat exchanger. If necessary, clean the nozzles and remove oxides from the burner. Remove deposits from the main heat exchanger to ensure they do not affect combustion behavior and thermal efficiency.

  • Provide pressure for the expansion tank to 1 bar.

  • Check the exhaust pipe for blockages and clean it.

  • Check the functionality of the water pump and fan.
.

  • Attention:
(1) When the boiler stops working due to a malfunction, check the water, power and gas supplies. If everything is in order, but the boiler does not work normally, contact qualified specialists.

(2) To avoid accidents, users should not remove the boiler and perform maintenance on it. We are not responsible for accidents caused by opening the boiler without our permission.

(3) This boiler must not be used without permission from a qualified authorized service center.

2017-07-11 Evgeniy Fomenko

Design and principle of operation of Weller boilers

Double-circuit mounted gas boilers Weller are designed for heating rooms up to 240 square meters. Maximum heat transfer, when operating at any power, allows the use of a modulating burner - the main advantage of the design of these boilers. Combustion chamber in appliances closed type, in addition, there is an additional condensation module, which also collects heat from the exhaust gases.

Human participation is not required during control, since all settings are performed automatically. Wall boilers Weller Mars connects to classic vertical chimney, and the removal of combustion products and intake fresh air occurs in a forced manner through a coaxial chimney.

In order to increase the performance of this brand, all its models are supplied with components from leading European companies - Wilo, SWEP, FUGAS, etc. If the device’s automation detects a malfunction, a corresponding signal is given to the display, where error codes are displayed.

All units are equipped with separate heat exchangers, and the control unit automatically controls the pipeline required pressure and installs best option work at which gas consumption will be minimal. During operation, it is necessary to study any Weller gas boiler. Errors that appear on the screen will help you identify the problem in time and quickly solve it.

Basic error codes

e1

Error e1 - insufficient water pressure or no water in the circulation system. The hydraulic unit is faulty - the rod may jam. Flow sensor microswitch is faulty. When the electricity is turned off, supply water again according to the instructions. Raise the pressure to 1-1.2 bar and turn on the heating.

Weller boiler hydraulic unit

e2

Error e2 - protection against overheating or faulty ignition has tripped. The boiler enters this mode at a water temperature of +95 degrees, or due to a faulty ignition. Check gas supply. Press “reset” and start the device again.

e5

Code e5 – software malfunction. Press the reset button or restart the device. If this does not help, call a specialist.

e6

Error e6 - the heating system sensor is faulty. The boiler entered protective mode due to improper operation of the sensor. Disconnect the device and replace the corresponding element. If necessary, invite a specialist.

e7

Code e7 – increase in coolant temperature. The protective mode is activated when the system temperature quickly rises to 95 degrees, as well as when the domestic hot water rises to 80 degrees. Disconnect from the power supply, and when the indicator drops 6 degrees less than the set value, start it with the “reset” button.

e9

Error e9 – triggered by a fault signal from the DHW sensor. Due to abnormal operation of the sensor, the boiler entered protection mode. Turn off power and replace sensor. Or call a specialist.

DHW flow sensor

Other faults

Sometimes when operating Weller boilers, the device suddenly begins to drop the temperature in the heating system. By 10, or even 20 degrees. It might even turn off completely. At the same time, it is connected to the electrical network through a stabilizer.

In such a situation, it is the stabilizer that should be checked. Quite often, such devices fail unnoticed, and the problem is revealed only when a breakdown of the consumers connected to them is detected. It is recommended to use a voltage stabilizer when connecting gas boilers.

Weller gas boilers - Operation, faults and error codes

Weller boiler error codes

Error E1– There is insufficient or no water pressure in the circulation system. There is a problem with the hydraulic unit, the rod may be stuck. The flow sensor microswitch is faulty. When there is a power outage, it is recommended to restore the water supply. Increase the pressure to 1.2 bar and start the heating.

Error E2– Triggering of protection against overheating or incorrect ignition. This mode is set in the device at a water temperature of +96 degrees, or due to problems with the ignition system. It is recommended to check the gas supply. Press the “reset” button to reactivate the device.

Error E5– Control board program malfunction. To resolve this, press the “reset” key to restart the unit. If the action is unsuccessful, you should contact the service center.

Error E6– Damage to the heating system sensor. Due to incorrect performance of the function by the sensor, the unit enters protective mode. It is recommended to disconnect the device from the network and replace this component. You can also call customer service.

Error E7Heat coolant. The protection cycle is activated in two cases: when the temperature of the heating system rises sharply to 97 degrees or when the temperature of the hot water supply exceeds the limit of 81 degrees. It is necessary to disconnect from the power supply system. If the indicator decreases by six degrees less than recommended, start with the “reset” key.

Error E9– Malfunction of the hot water sensor. Due to improper functioning of the DHW sensor, the unit enters protective mode. It is necessary to disconnect it and replace the hot water supply sensor or contact a service center.

In some cases, when using the unit, it can reduce the temperature by ten or fifteen degrees in the heating system, and sometimes even turn off. IN in this case The device must be connected to the electrical network using a stabilizer, so it is this that needs to be checked. Since the stabilizer itself may fail, and a malfunction may appear only when a problem is detected in the energy consumers connected to it.

Weller boiler repair assistance

For country house I would like to install a wall-mounted gas boiler Weller Mars. Please tell us what is the nominal gas supply pressure /methane/propane/ for these models?

In this type of equipment, the nominal gas supply pressure for methane/propane is 20/37 mbar.

We use this brand of boiler indoors. He had been doing well until this evening. Currently, 5 seconds after the start, the device began to go out. It seems that it cannot deliver water to the system. Explain what the problem is?

Probable cause Such a defect may be an ignition electrode that does not see the fire, or a decrease in circulation.

I had a mars 32 OC double-circuit boiler installed. When started, the burner ignites and immediately goes out. I believe there is no ignition spark. Can you help me remove this error?

It is necessary to check whether a sound is heard when an ignition spark is formed if the wire is removed for ignition. If there is no sound, you must change the ignition transformer. If there is sound, replace the ignition electrode or burner.

I connected this device at the end of 2016. Supposedly after five months a failure occurred. I adjust the temperature, but it doesn’t hold it. Explain what could be?

Perhaps the automation fails, and when the temperature rises by 65 degrees, the nozzles turn off. It is necessary to adjust the automation for correct execution functions. Another factor may be that the power of the unit is not matched in relation to the heated area.

The Mars 32 gas boiler operates intermittently in DHW mode (practically does not work). He exhibits unusual behavior. When you turn on the DHW tap, the water heats up almost to boiling water, despite the fact that the sensor reads +40 degrees. After 2-3 minutes the boiling water turns off and cold water flows. After 2-3 minutes it turns on and brings the water temperature to boiling water again. And so 4 times. After the last heating to boiling water it displays cold water and will not turn on again. The heating circuit is working normally (I haven’t checked it for a long time - it was summer). After I turn off the boiler, and it stands for about 2 days without power and with the water supply tap closed, it turns on, and again the same troubles. What needs to be done, can something change?

You need to replace the temperature sensor.

I came across a Weller boiler for repairs. A few seconds after turning it on, it displays error E1. Power is not supplied to the pump. The pump is running, the winding and capacitor are ringing. There is no power coming from the board. Has anyone encountered this problem in their practice?

We need to start with the fact that this model polls the coolant flow sensor twice. Before starting the pump, it must be open, and then closed. If any of the conditions are not met, error E1.

Boiler Weller Mars 26. Gives error E02, ignition error. The flame lights up and goes out. At removed cover The combustion chamber is working fine. As soon as you close the lid, it goes out. The chimney is clean, the fan, pneumatic relay, gas valve, ignition electrode, and ignition unit have been replaced. Nothing helped. The electrical network is normal. Who can help?

For turbocharged models, it should be the other way around. I would venture to guess that there is either an excess or a severe lack of air.

Weller mars 26 boiler. It cycles a lot during operation. For example, the heating costs 40 degrees, it turns on, quickly heats up to 38-40 degrees, the burner goes out, the temperature quickly drops to about 32-33, and the burner starts again and so on in a circle. If I increase the temperature, for example to 48, the unit heats up for a long time (on the display the same temperature is around 49-50 or even drops by a degree). When all the water in the batteries heats up, the burner goes out, and then the temperature slowly drops. The burner turns on, and now it begins to clock again. What thoughts? Poor flow in the heating system? Does it have a filter? Gas not regulated? And is there any way to increase the delta?

It looks like a typical malfunction of the electronic board, when the unit stops modulating the flame and heats at maximum.

Mars 26 boiler. The boiler does not start. It doesn’t write anything (it shows two zeros), it doesn’t respond to resets, and the power button turns off the display. The unit is double-circuit, the water circuit is closed with two plugs. Gas is normal. The pressure in the system is 1.5-2 atm. The boiler turned off because there were problems with the gas supply, the pressure dropped to 0, but it did not show any errors. Last time there was a similar situation: the light was turned off for half a day, the pressure dropped, it did not turn on, it gave an error (low pressure). I raised the pressure, but it still wouldn't turn on. It rumbles twice and then stands still. Somehow it happened (I pumped in more than 2 atm pressure and then decided to bleed it down a little to 1.5) that the next time I turned on the electric plug, the unit immediately started turning the pump and then turned on. But this time nothing happened. What could it be?

There was a similar problem. The boiler gave error E6, apparently it lacks draft or the exhaust is bad, I pulled out the tubes from the sensor to the fan. I stuck one tube onto the fan and the piezo clicked. I made a reset, the device was quickly tested, started the fan and lit the burner. I didn’t plug in the second tube, I waited about two hours until the system and chimney warmed up well internal air. Turned it off, then installed all the tubes as they were, turned it on, and it started up fine.

Please help me with the problem: the mars 32 OC boiler does not turn on, it shows error E1 (lack of pressure in the heating system). The pressure is normal, above 1 bar, the pump does not start, a faint click is heard. The red LED on the DHW flow sensor is on, although I don’t use the DHW, the output there is muted, and through the input I only recharge the unit.

First, look at the DHW flow sensor, clean or replace the bronze screw-in “cartridge”. Then look at the heating flow sensor. Most likely, it is filled with water. It is necessary to change the oil seal and dry the microswitch.

A year ago we connected to the system this device. Today, at the moment of start-up, the wick lights up for 10 seconds, but the main burner does not pick up the fire, and the unit goes out. How can you get out of the situation?

The ignition machine is probably not working properly or there is a problem with the burner. Just in case, look to see if the phasing was lost when connecting to the power supply.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

OPERATION AND REPAIR OF BOILERS


Are they really Chinese? heating boilers- is this low-quality technology by default? The majority of buyers in the Russian Federation have a strong opinion that this is not without reason. But this stereotype can be destroyed by considering the technical characteristics of Weller gas heating boilers.

The main difference between Weller brand products is their undoubted quality, reliability and ease of use. One of the best proof of the model’s popularity is that the company’s thermal generators are popular not only in the Russian Federation, but also among more demanding European buyers.

Chinese brand Weller

Initially, Weller was presented as an Italian manufacturer. Over time, products began to be produced in China. Today Weller is owned by a Chinese company.

Surprisingly, the manufacturer managed to do what other concerns were unable to do - maintain European quality and technical characteristics, making the cost of production lower and, accordingly, more attractive to the consumer.

The produced models are focused on apartment heating of the house. The consumer is offered mounted models, double-circuit type with closed camera combustion.

Mounted boilers in demand on the market

If we look at the statistics, it becomes clear that for the average consumer, the most attractive choice is mounted models of heating equipment. The number of sales of units that can be hung on the wall significantly exceeds the sales of boilers that require installation on the floor. This is especially obvious in the case of apartment owners multi-storey building who want to make autonomous heating.

What explains the popularity of the boiler models presented by Weller?

Judging by customer reviews, the only weak point of the Weller thermal station is the vulnerability of the control unit to voltage surges in the network. You can ensure safety by installing a UPS.

Main principles of installation and use

When developing this model, the manufacturer primarily focused on producing a boiler that would be easy to install and maintain. As a result, installation does not require compliance special conditions and connections additional equipment, runs quite quickly.

No adjustment or tuning of the boiler is required after installation. The control unit automatically monitors the pressure in the pipeline and selects the optimal option for operation, such that the natural gas consumption is minimal.

The operation of the Weller boiler depends on some factors that will need to be taken into account before installation:

  • Compliance with the manufacturer's recommendations and requirements. For example, a supply and exhaust adapter is installed in the smoke removal system, which monitors the presence of draft in the chimney. Violations during the installation of the coaxial pipe lead to failure of the automation to turn on the boiler.
  • Connection to the electrical network and installation of temperature sensors must be carried out by a qualified specialist.

Ease of operation is achieved thanks to the system of “intelligent” control of the boiler operation. The installed controller independently makes decisions about changing the operating mode depending on external and internal factors, making the operation of the device as comfortable and economically profitable as possible.

Get rid of the prejudices that China is of poor quality

The example of Weller equipment proves that China is not always bad, and sometimes even very good. Full automation of the heating process, adaptation to domestic conditions, no need for self-adjustment pressure, smart automation - all these functions put the company’s models on a par with their European counterparts.

The boilers were designed for apartment heating, can be installed in small rooms, without the need to use a separate boiler room for these purposes. A good choice for residents of an apartment building!

This article contains all possible malfunctions and options for eliminating them, as well as error codes for Weller boilers. All information is read in the following order: code - name - possible malfunction. If you have any additional questions, please leave them in the comments to this article.

If you are not 100% sure what exactly the problem is and that you can solve it, immediately contact the service center to diagnose and fix the problem.

You can find out the price and buy heating equipment and related products from us. Write, call and come to one of the stores in your city. Delivery throughout the Russian Federation and CIS countries.

Weller wall-mounted double-circuit gas boilers are used for heating systems in rooms up to 230 sq. meters. The modulation burner allows you to achieve the greatest heat transfer when operating at any power, which is the main advantage of the design of this brand. The unit has a closed combustion chamber, as well as an additional condensation module that absorbs heat from the exhaust gases.

The controls are simple and intuitive; almost all adjustments are performed automatically. Wall models Mars are connected to a standard vertical chimney, and combustion products are removed and air is taken from the street in a forced manner using a coaxial chimney.

To maximize the performance of these models, they are equipped with parts and components from famous companies Europe. If the automation detects any malfunction, a symbol with an error code is displayed on the display. All models are equipped with separate heat exchangers.

The control unit, in automatic mode, monitors the required pressure in the pipeline and sets the most favorable operating mode, in which gas consumption will be the least. Before use, you must read the instructions. Error codes that appear on the display can help you detect and eliminate the malfunction in a timely manner.

Error code E1 - Pressure error

There is insufficient or no water pressure in the circulation system. There is a problem with the hydraulic unit, the rod may be stuck. The flow sensor microswitch is faulty. When there is a power outage, it is recommended to restore the water supply. Increase the pressure to 1.2 bar and start the heating.

Error code E2 - Protection against overheating or incorrect ignition has tripped

This mode is set in the device at a water temperature of +96 degrees, or due to problems with the ignition system. It is recommended to check the gas supply. Press the “reset” button to reactivate the device.

Error code E5 - Control board program malfunction

To resolve this, press the “reset” key to restart the unit. If the action is unsuccessful, you should contact the service center.

Error code E6 - Damage to the heating system sensor

Due to incorrect performance of the function by the sensor, the unit enters protective mode. It is recommended to disconnect the device from the network and replace this component. You can also call customer service.

Error code E7 - High coolant temperature

The protection cycle is activated in two cases: when the temperature of the heating system rises sharply to 97 degrees or when the temperature of the hot water supply exceeds the limit of 81 degrees. It is necessary to disconnect from the power supply system. If the indicator decreases by six degrees less than recommended, start with the “reset” key.

Error code E9 - DHW sensor error

Malfunction of the hot water supply sensor. Due to improper functioning of the DHW sensor, the unit enters protective mode. It is necessary to disconnect it and replace the hot water supply sensor or contact a service center.

In some cases, when using the unit, it can reduce the temperature by ten or fifteen degrees in the heating system, and sometimes even turn off. In this case, the device must be connected to the electrical network using a stabilizer, so it is this that needs to be checked. Since the stabilizer itself can fail, and a malfunction can only appear when a problem is detected in the energy consumers connected to it.