Maximum flow speed 10 m/s.

ERSV-4x0x V- without indicator;
ERSV-5x0x ​​V- with indicator.

Connection type:

ERSV-xx0L V- “sandwich” (from DN 10 to DN 150);
ERSV-xx0F V- flanged (from DN 20 to DN 300).

Maximum flow speed 5 m/s.

Measuring unit versions:

ERSV-440L V- without indicator;
ERSV-540L V- with indicator.

Connection type:

ERSV-x40L V- “sandwich” (DN 25, DN 32, DN 50).

Distinctive features:

  • ease of installation: low weight as a result of the use of special materials, the ability to rotate the indicator during installation, no need to install a filter;
  • mechanical strength;
  • easy setup for working with heat meters without using a computer;
  • maximum security of measurement results from unauthorized access and interference in the operation of the device;
  • event log (recording changes in settings, recording changes in operating modes, changing date/time);
  • eliminating errors associated with emptying the pipeline or power failure;
  • thanks to the built-in RFID tag of the NFC standard, you can take readings from the device using a smartphone;
  • real time clock;
  • The largest selection of DNs in its class ensures that costs can be minimized when working with a single instrument supplier, even in large, complex projects;
  • full bore flow meter without pressure loss in the measuring section;
  • no filter installation required;
  • possibility of installation in plastic (metal-plastic) pipelines;
  • output information to two universal outputs with the ability to select an operating mode (pulse, frequency or logical);
  • increase in switching current at universal outputs in passive mode up to 150 mA;
  • operation of universal outputs in passive mode with any polarity of external voltage (analogue of a “dry” contact);
  • short straight sections before and after the flow meter;
  • improved flow path for stable operation in the low flow zone ( maximum speed flow 5 m/s);
  • no additional connecting fittings (diffusers and confusers) are required;
  • degree of protection IP65;
  • control of pipeline filling.

Information output:

  • to a symbolic liquid crystal indicator (only for versions ERSV-5x0x ​​V and ERSV-540L V);
  • in the form of pulses with normalized weight and a logical flow direction signal;
  • via serial interface RS-485 (optional);
  • via NFC wireless interface (optional).


The company's products have always met the standards of quality and manufacturability. These criteria are no exception for liquid flow meters. Electromagnetic flowmeters have a number of advantages over analogues offered by other manufacturers:

  • The devices are reliably protected from harmful effects environment;
  • Operation of electromagnetic flow meters in real conditions does not cause difficulties and additional technical means;
  • Durable protection from external factors that can affect the quality and stable operation of the equipment.

Electromagnetic flowmeters Takeoff will help you cope with your tasks. If you were able to quickly resolve the issue of organizing water consumption metering units, then the next step for you will be a high-quality selection of the measurement method itself and equipment specializing in this. Buyers are not always “savvy” for optimal choice and then our specialists can come to your aid.

An electromagnetic flow meter or other metering device has its own specific technical data and characteristics. This kind measuring instruments always have their own physical quantity and a small margin of error. These devices can quickly and accurately measure the volume of liquid that is passed through them. Having an electromagnetic meter in the flowmeter increases the technical accuracy of the measured medium.

Electromagnetic flowmeters Vzlet are easy to use using the electromagnetic method, which is by far the most universal and accurate. This method can easily measure pressure flows of any complexity. The essence of such a measurement is always to measure the force of electrical movement, which necessarily occurs in all flows of any liquid. A similar method was developed back in the nineteenth century, and today our modernized liquid flow measuring and metering devices will always come to your aid.

Electromagnetic counter Takeoff

Using equipment with this method always has its positive and negative sides.

Positive features and advantages of this method:

  • High versatility in application;
  • High stable accuracy rates;
  • The quality of the measured flows does not affect the final result;
  • Ease of method for measuring wastewater;
  • No data loss during measurements.

The disadvantages of this method are quite minor. These include:

  • The cost of electromagnetic flow meters Takeoff always depends on the diameters of the water pipes;
  • In the presence of strong electromagnetic fluxes, the error scale may fluctuate.

Before making the final choice of flow meters or heat meters Vzlet, clearly define for yourself the scale of the tasks. This will allow you to correctly and wisely focus on the product range that is offered to your attention by our company. The knowledge you can gain in the field of water supply and sanitation will always help you do right choice when purchasing instruments for measuring and metering liquid flow. Good result will always be achieved with a high-quality approach to this issue and reasonable selection of equipment. A properly selected measuring device will cope with its tasks; it does not fail for a long time and is easy to use. maintenance. Each task that concerns a logical and correct measurement must always be thought out individually. And we will be happy to help you solve it!

Computer-aided development software project documentation and automatic configuration of the device according to the project. Provides the creation of a configuration base for heat meter-recorder TSR-024, -024M.

System requirements
RAM: 512 MB
operating system Windows XP, Windows 7
MS Office 2003 and higher.

Description

To create a project, it is enough to fill out information about the subscriber and a table of contractual parameters (Fig. 1).

Rice. 1

The choice of scheme is made from 10 standard templates, as well as a custom scheme (Fig. 2).


Rice. 2

Emergency situations and reactions to them are automatically installed when selecting a scheme.


Rice. 3

The pipelines are configured automatically. Depending on the selected scheme, the values ​​of the upper and lower temperature settings are set. Contractual values ​​of temperature, pressure, energy for heating system and domestic hot water are calculated based on a table of contractual values ​​and parameters. The contractual volume flow values ​​are calculated based on the contract mass flow value (Fig. 4).


Rice. 4

The flow converters are configured by selecting the flow meter model. Currently, the entire line of electromagnetic flow meters of JSC Vzlet is supported (Fig. 5).
There is also the option to create a custom template. For example, for ultrasonic flow meters, parameters included in the database are entered. Further adjustments are made during commissioning works.


Rice. 5

Upon completion of the work, a configuration base is created in the form of an MS Word document (Fig. 6), and a configuration file.


Rice. 6

The configuration file is loaded into the heat calculator, then the data is verified, which significantly reduces commissioning time.
The configuration base checksum (CRC) is calculated for all 609 basic parameters, taking into account the values ​​they accept. Match the project checksum with the value displayed by the heat meter in the menu About the device, means complete coincidence of all parameters of the base in the device with the project created in KB TSRV-024M. The introduction of a checksum will allow you to avoid parameter verification and reduce the time of object acceptance.

Electromagnetic flow meter Vzlet ERSV-540L-V Du 25(Vzlet ER light M series) is designed to measure the average volumetric flow rate and volume of hot and cold water, household waste, as well as other non-aggressive electrically conductive liquids in a wide range of temperatures and conductivities.

The main scope of application of the Vzlet ERSV-540L-V Du 25 flow meters is as part of heat meters, measuring systems, automated systems management technological processes in energy, public utilities etc. Flowmeters Vzlet ERSV-540L-V Du 25 can be installed in both metal and plastic (metal-plastic) pipelines. Upon request, the Vzlet ERSV-540L-V flow meters can be configured to measure reverse flow parameters and issue a flow direction signal.

The Takeoff ER (Light M) series has a built-in indicator, the connection type is “sandwich”. Provides measurement of average volume flow with a permissible error of ±2%. Range of measured average volumetric fluid flow - 1:250

Features of flow meters

Flow meter Vzlet ERSV-540L-V Du 25 has distinctive features compared to similar devices:

  • ease of installation: low weight as a result of the use of special materials, the ability to rotate the indicator during installation;
  • mechanical strength;
  • easy setup for working with heat meters without using a computer;
  • maximum security of measurement results from unauthorized access and interference in the operation of the device;
  • eliminating errors associated with emptying the pipeline or power failure;
  • thanks to the built-in RFID tag of the NFC standard, you can take readings from the device using a smartphone;
  • real time clock;
  • The largest selection of diameters in its class ensures the ability to minimize costs when working with a single instrument supplier, even in large complex projects;
  • full bore flow meter without pressure loss in the measuring section;
  • no filter installation required;
  • possibility of installation in plastic (metal-plastic) pipelines;
  • output information to two universal outputs with the ability to select an operating mode (pulse, frequency or logical);
  • increase in switching current at universal outputs in passive mode up to 150 mA;
  • operation of universal outputs in passive mode with any polarity of external voltage (analogue of a “dry” contact);
  • short straight sections before and after the flow meter;
  • improved flow part for stable operation in the low-flow zone (maximum flow speed 5 m/s);
  • no additional connecting fittings (diffusers and confusers) are required;
  • degree of protection IP65;
  • pipeline filling control

Archiving parameters of the flow meter Vzlyot ER (ERSV)

Flow meter Takeoff ERSV-540L-V Du 25 series Takeoff ER (Light M) ensures storage of work results in archives:

  • sentry - 1440 records (60 days),
  • daily - 365 records (1 year),
  • monthly - 72 records (6 years).

Reading archives is possible on Personal Computer By RS-485 interface or using a USB-ER converter. The storage life of installation information in the flow meter when the external power is turned off is at least 1 year. Changes in all metrologically significant parameters of the flow meter are recorded in the event log. Log depth – 3000 records. The flow meter also provides a system for diagnosing failures and emergency situations that arise during operation and are associated with factors such as emptying of the pipeline, exposure to an external magnetic field, and contamination of the electrodes.