Mimax gas boilers: review, model range, automation

For heating residential and non-residential premises, medium and large areas Floor-standing gas boilers are most often used. They are among a huge range of heating equipment, which also includes solid fuel, diesel and electric boilers, have a low cost of ownership. It consists of the relatively low price of floor-standing gas heating boilers themselves, inexpensive service and fuel efficiency, i.e. gas

It is often difficult for a buyer to figure out on his own what kind of domestic boiler he should buy. Self review equipment market, reviews of other consumers, advice from professionals will certainly lead him to the conclusion that he needs to buy products domestic manufacturer– floor-standing gas boilers “Lemax”.

Our company is ready to offer competitive prices and a wide range of products manufactured according to modern technologies using components from leading global manufacturers. In particular, on heating boilers Lemax installs a gas burner device based on SIT automation. It ensures stable operation of the boiler and gas savings.

The Lemax company produces two types of floor-standing gas boilers:

  • Single-circuit boilers - intended only for heating premises.
  • Double-circuit boilers also allow you to provide heating of water for domestic needs.

Without exception, all products are different high quality and trouble-free operation for a long time. Correct operation equipment and prompt elimination of possible malfunctions in its operation are guaranteed by an extensive network service centers. In almost all regions of Russia, they provide not only warranty, but also post-warranty maintenance of boilers, as well as resolution of all issues related to the purchased equipment.

Where to buy Lemax floor-standing boilers

We invite you to buy Lemax floor-standing gas boilers directly from the factory or by contacting a dealer in your region.

Floor steel gas boiler Mimax CSG produced in Taganrog is widely used in our country due to its simplicity of design, efficiency and low price. Thanks to a wide range of powers from 7 to 40 kW, this type of boiler is capable of heating a private house or other premises with a total area of ​​30 to 400 square meters.

In addition, Mimax gas boilers have good reviews due to their compact dimensions, quite nice appearance and high efficiency. They can operate both on natural gas and, when replacing (injectors), on liquefied gas.

Model range and description of gas boilers KSG "Mimax"

Boilers from the Taganrog manufacturer differ in their intended use:

- single-circuit

- double-circuit

Single-circuit floor-standing gas Mimax boilers are intended for heating only. They have one circuit; on the back of the device there are fittings for connecting the coolant (direct and return), with a diameter of 40 or 50 mm. These boilers are marked KSG.

Mimax floor-standing gas boilers

Depending on the power, they can be designated as follows: KSG-7, KSG-10, KSG-12.5, KSG-16, KSG-20, KSG-25, KSG-31.5, KSG-40. What do these letters and numbers mean?

KSG is a Steel Gas Boiler, the numbers behind these letters convey to us information about the power of this heating apparatus. The boilers are also different technical characteristics. For example, the abbreviation KSG-10 indicates that this boiler is single-circuit, with a power of 10 kW, and a heating area of ​​up to 90 square meters.

Double-circuit floor-standing gas Mimax boilers can be used for both heating and hot water supply. They, accordingly, already have two circuits. The second circuit for hot water supply is heated by the main heat exchanger, where the coolant itself is heated. The water in the circuits does not mix.

According to the instructions, Mimax double-circuit boilers have a slightly different designation, namely KSGV. The decoding indicates that this is a steel gas hot water boiler (hot water). In stores you can find the following options: KSGV-12.5, KSGV-16, KSGV-20, KSGV-25, KSGV-31.5 and KSGV-40.

The connections for connecting the circuit are also located on the rear side and have a diameter of 1/2 inch. Minimum power Mimax double-circuit boilers are 12.5 kW, in contrast to single-circuit boilers, for which this parameter is 7 kW.

Double-circuit boilers, like single-circuit boilers, have a special thermometer on the front side that shows the temperature value on a scale from 0 to 120 degrees Celsius.

Construction of the KSG Mimax boiler


How to choose a floor-standing gas boiler

KSG Mimax boilers for heating are selected according to the area of ​​the house and are divided according to thermal power. Models from 7 to 40 kW are available on the Russian market. Do not forget about the rule of 1 kW per 10 sq.m., which we also apply to.

For example, if you need to heat a private house with an area of ​​100 square meters. meters, then you need to buy a KSG-12.5 or KSG-16 boiler, if with a reserve, etc.

When choosing a double-circuit floor-standing boiler, you need to take into account that in order to obtain a normal amount of hot running water, you need to buy a boiler with a capacity of at least 20 kW. Such a gas boiler will produce approximately 7 liters of water per minute, at a temperature of about 35 degrees.

This is a disadvantage of most floor-standing double-circuit boilers, because for heating small house, for example, 50 square meters, a KSG-7 boiler is quite enough.

Using a 20 kW thermal apparatus, in in this case, turns out to be somewhat irrational due to the higher consumption of natural or bottled gas. Or you need to purchase a wall-mounted one with good performance hot water.

Automation for gas heating boilers KSG

KSG floor-standing boilers are available in two types gas burners:

— gas burner device AGU-T-M

— gas burner device AGU-T-E-I(R) type Euro SIT

KSG boiler with automatic control AGU-T-M

AGU-T-M device consists of the following main elements:

- gas valve with start button
— block tap with adjustment knob
— gas distributor
— thermal cylinder
- temperature sensor

How to properly use automatic equipment like AGU-T-M

1. Before lighting the igniter, move the damper.

2. Press the gas valve button and light the igniter. At this time, the bimetallic plate is heated.

3. Without releasing the button, wait a few seconds until the lever moves to the “on the button” position.

Device AGU-T-E-I(R) type Euro SIT

This type of boiler automation involves ignition, either from a match or lighter, or from a special piezoelectric element. To adjust the temperature of the coolant in the boiler, there is a handle with a scale. When starting the boiler, simply move the handle to the desired position and press the piezo button.

KSG boiler with Euro SIT automation


Automation with piezo ignition is completely energy independent, as well as simple automation type AGU-T-M.

Possible malfunctions in the operation of KSG Mimax gas boilers:

Try cleaning the chimney possible reason- poor traction

Check the boiler automation settings are correct

Insufficient amount of coolant in the system or incorrect installation of the heating system

Watch the video:

Description

Boilers KSG, KSGV are designed for heat supply residential buildings with a total area of ​​up to 250 m2 with a ceiling height of 2.7 m and hot water supply in the presence of a water heater. Powered by natural gas low pressure in automatic mode based on coolant temperature.

When using domestic gas heating boilers of the KSG model in heating systems, the following is achieved:

  • energy saving (gas consumption is reduced by up to 30%) due to the built-in gas pressure stabilizer;
  • reducing the amount of harmful emissions into the atmosphere;
  • increasing control accuracy temperature regime in room.

Domestic gas boilers KSG, KSGV have 3 degrees of protection in emergency situations:

  • when the flame on the pilot burner goes out;
  • in the absence of traction;
  • when gas supply stops.

Domestic gas boilers KSG, having the letter (B) in the designation, are double-circuit heating boilers, i.e. have a built-in water heater providing hot water supply. Double-circuit heating boilers KSGV, and single-circuit boilers KSG heating systems are produced in the design of gas floor heating boilers.

These KSG floor standing gas boilers are supplied with a highly efficient steel heat exchanger. For the most optimal removal of gas combustion energy by a convective heating surface, the method of extensive high-speed heat removal is used with a smaller volume of coolant in the boiler, thereby achieving high efficiency.

A gas pressure stabilizer built into the gas block of a domestic boiler ensures uniform combustion gas-air mixture on the main burners with constant heating output, regardless of the gas pressure in the network. Main gas burners made of heat-resistant of stainless steel with slotted grooves are placed evenly under the heat exchanger, creating a uniform thermal field in the combustion volume, which eliminates the formation of local overheating zones of the heat exchanger and its destruction.

The draft interrupter (draft stabilizer) equalizes the air pressure in the suction zone into the ejector of the main gas burners and near the exit of the gas-air mixture from the slotted grooves when the location in the firebox is open without adjustment, and also prevents the pilot burner from blowing out during a short-term overturning of the draft. energy independence

Advantages of domestic gas heating boilers KSG, KSGV

  • These OCHAG brand boilers have a highly efficient steel heat exchanger, which allows them to achieve high efficiency.
  • The design and small dimensions of the domestic boiler, hidden automation, allow it to fit harmoniously into any room interior.
  • Modern design and technological developments, used in this heating boiler, make it easy to maintain and operate.
  • Complete energy independence from external sources electricity.
  • Multi-level quality control makes the household heating boiler reliable and durable.
  • The domestic heating boiler KSG, KSGV is designed for heating residential premises and hot water supply in the presence of a water heater.
  • Ability to operate at reduced gas pressure.
  • The heating boiler does not require adjustment during atmospheric changes [since All gas combustion processes are automated].
  • There is a draft stabilizer that maintains constant pressure in the firebox, and a gas pressure stabilizer that maintains constant power of the main burner.
  • There is an option to configure a gas floor-standing boiler with SABK-E electronic automation.

Documentation for the focus of the CSG

Parapet boiler KSG/KSGV-P Luch with closed camera combustion, universal (right/left) connection to the heating system and the ability to select hot water for domestic needs (second circuit).

A feature of this type of boilers is the combustion chamber is isolated from the room - air for the combustion process is supplied from the outside through a special coaxial chimney (pipe within a pipe).

The boiler is equipped with modern gas automation TGV307 (a complete analogue of the Italian EUROSIT630).

Ideal for installation in private houses and apartments.

Specifications
Model KSG/KSGV-8/P KSG/KSGV-10/P KSG/KSGV-12/P KSG/KSGV-16/P KSG/KSGV-20/P
Thermal power, kW 8 10 12 16 20
Heated area, m2 80 100 120 160 200
Gas consumption, m 3 / h 0,8 1 1,2 1,5 1,9
Efficiency, % 92
Working pressure, MPa 0,19
Inlet gas pressure, Pa min-600/max-2800
Air duct size, mm 216x234
Building wall thickness, mm 270-455
Dimensions, mm 750x570x320 830x640x410
Weight, kg 50 80

Detailed description

The parapet gas boiler KSG/KSGV “LUCH” is a modern heating equipment with compact dimensions and a closed combustion chamber. The air involved in the combustion process enters and is removed through one coaxial type chimney. The air flows in such a chimney are divided: the outer one works to supply fresh air, the internal one removes exhaust gases.

The small dimensions of the equipment allow it to be installed even in cramped rooms with small area. A gas boiler with a closed combustion chamber “LUCH” can be connected to communications on the left or right side. Pipes for connecting gas, heating and water supply pipes are located both on the left and on right side. Those pipes that are not in use are closed with plugs.

Isolated combustion chamber

A boiler with a closed combustion chamber is gas equipment for heating, in which the gas burner device is located in a compartment isolated relative to the room. Thus, the air from the interior of the room is not used during boiler operation. Special device coaxial chimney allows you to heat the incoming air, thus reducing heat loss.

The parapet gas boiler “LUCH” KSG/KSGV, thanks to the closed chamber and the coaxial type of chimney, can be installed on any wall. It does not require planning and organizing a traditional chimney; the terminal is displayed on any external wall in compliance with the distances from the window, ground and neighboring buildings specified in the passport. It is not allowed to lead the chimney into the entrance, onto the balcony or loggia. A boiler with a closed chamber does not require additional ventilation; it can even be installed in small room(for example, in the kitchen).

Tubular heat exchanger

Reducing the size of the heating system gas boiler"LUCH" did not affect its performance and efficiency. The efficiency of a parapet boiler is at least 92%. This was achieved, among other things, thanks to the special structure of the steel tubular heat exchanger. For the maximum possible heat removal, the heat exchanger is equipped with an optimal number of vertical tubes. The heat exchanger itself is made of durable, heat-resistant stainless steel 2mm thick. All these factors made it possible to significantly extend its service life.

Gas automation TGV307 (similar to EUROSIT630)

A reliable, time-tested automatic system - TGV307 (a complete analogue of the Italian EUROSIT630) controls the gas supply and is responsible for the safety of parapet gas boilers. Gas automatics TGV 307 are autonomous and do not require connection to the electrical network. Automatic TVG307, depending on the readings of the coolant temperature sensor, modulates the flame of the main burner, thus regulating the power.

Automation ensures the safe operation of gas heating equipment and produces an instant protective shutdown in the following cases:

  • Blockage, lack of traction;
  • Pressure drop below 600 mPa, gas supply stops;
  • Overheating of water (other coolant) in the system;
  • Flame extinguishment on the pilot burner.

The automatic gas burner device is located in the front part of the parapet gas boiler (as in models with an open combustion chamber). This simplifies its removal, maintenance and repair of heating equipment. The burner is made as a “pipe in pipe”. Before being supplied to the main outer tube of a larger diameter, the gas passes through the inner one. In the inner tube, preheating and preparation of gas for combustion occurs. This approach can significantly reduce fuel consumption and increase efficiency.

Purpose of heating boilers KSG/KSGV "LUCH" parapet

Parapet boilers "LUCH" can help solve the issue of heating and preparation warm water. Models marked KSG are equipped with one circuit and are intended for heating only. Equipment marked KSGV has two separate circuits - for heating and water treatment, so on their basis it is possible to organize reliable system heating and hot water supply for domestic needs.

One and double-circuit boilers with a closed combustion chamber "LUCH" are produced in the power range from 8-20 kW, which allows you to choose optimal solution for rooms ranging from 80 to 200 m².

Gas boiler hearth is a product of the ServiceGaz plant. This is a floor-standing unit designed for heating any type of housing - private houses or apartments. The maximum heating area for one unit of equipment is 1000 sq. m. When developing the device, the features and problems that periodically arise on domestic gas mains were taken into account. Provision is made for operation in conditions of low fuel pressure.

About company

The ServiceGAZ company, which owns the Ochag trademark, was founded in 1993. Its location is Ulyanovsk. It produces gas equipment - more than six dozen modifications of boilers. Products attract loyal domestic consumers pricing policy. The average estimated cost of gas-powered devices is 14-17,000 rubles. All water heating equipment at the Ulyanovsk plant meets the European standard ISO 9001-2011. The manufacturer presents versions designed for heating housing of different sizes - from 70 to 1000 square meters. m.

Advantages of boilers from ServiceGaz

Automation makes using boilers from the Ulyanovsk plant comfortable. Heat consumers completely shift the task of maintaining a given mode to the electronics. Advantages of all modifications of “Hearth”:

  • Economical gas consumption. The developers have included a stabilizing device in the design to equalize fuel pressure. Thanks to the stabilizer, gas consumption is reduced by 30%.
  • Environmental friendliness. Minimal emissions of harmful substances. In this regard, the equipment from ServiceGaz is not inferior to its European counterparts, which is quite unusual for domestic gas equipment.
  • Precision temperature control.
  • Three levels of security:

— protection against unexpected flame extinction in the burner;

— shutdown in the absence of traction;

— protection against lack of gas in the system.

  • Steel heat exchanger. High efficiency.
  • Simple but stylish design. Fits well in modern interiors, does not look like a foreign body, bulky or ugly.
  • The design uses innovative technologies. High technical equipment.
  • Low price. Simple and cheap maintenance.
  • Not needed additional sources energy.
  • High quality build. Multi-level quality control.
  • Adaptation to domestic gas supply conditions.
  • Italian automation EUROSIT.
  • Compactness.
  • Temperature adjustment.
  • System remote control. Can be controlled using mobile phone. An electric horn and the ability to connect to a “smart home” system are also provided.
  • The package includes a passport and instructions.

Device

Their feature and advantage is the ability to adapt to any heating system. The user can:

  • reinstall the front door depending on the need - on the right or left;
  • supply the coolant from a convenient side - from behind or from the side, thanks to two return lines.

Consists of the following components:

  • housings;
  • automation;
  • heat exchanger;
  • second circuit (provided that the boiler is double-circuit);
  • security systems.

Design in three parts:

  • The lower part contains a combustion chamber, which is closed from the side and back by a water jacket. Above the firebox is a heat exchanger. Thanks to the flame tubes of the latter, efficient heat transfer and heat exchange between exhaust gases and water is ensured.
  • The upper part contains a smoke extractor and a built-in draft stabilizer.
  • The middle part has a partition that ensures stable operation regardless of the ambient temperature.

The tandem of a smoke eliminator and a heat exchanger makes the boiler intellectually self-sufficient - it can function without any user intervention, without the need for manual adjustments. Stability of operation during traction instability is ensured by the stabilizer rod.

In the firebox there is a burner manufactured by ServiceGaz. Components– front panel, burner pipes, safety sensors – flame and draft, control unit SABC AT. Under the pipes there is a grille damper that supplies secondary air to the burner.

Important! Installation of the device indoors should be carried out with free access of air through the bottom of the device to the burner pipes.

Marking

All versions of the line can be divided into 4 groups:

This is non-volatile equipment capable of operating in closed and closed heating systems. open type. Coolant circulation - forced or natural. Next to the abbreviation - marking, there is a number indicating the power - 7-35 kW. The marking also indicates the type of automation:

  • T or AT – SABC AT;
  • C – SABC S RD;
  • E or EM – Eurosit.

Almost all modifications are made in accordance with current trends in minimalism. There is a pressure gauge in front, and other automatic elements are hidden in the housing. Distinctive feature products from ServiceGaz - White color. The radiator is made of steel, the burners are made of heat-resistant stainless steel. Equipped with a condensate collection device.

How to light it?

The ignition sequence is carried out by turning the control knob clockwise. Further procedure:

  • You need to turn the knob until the mark is pointing towards the pointer.
  • Next, press and hold the “Start” button.
  • The piezo ignition button must be pressed until it clicks. The igniter lights.
  • Keep “Start” pressed - waiting for the thermocouple to warm up. On the igniter, the gas block operates in auto mode.
  • Turn the knob counterclockwise to the required temperature.

How to choose?

Options for the material of manufacture of the heat exchanger - the container where the coolant is heated:

  • Steel. Good ductility, minimizing the likelihood of cracks due to thermal stress. Used in budget models. The service life is short due to susceptibility to corrosion.
  • Cast iron. Heavy weight. They cost more than steel ones. Minus - they react to temperature changes. They don't rust - a plus. They serve for about half a century.
  • Copper. They weigh little. Corrosion resistant. They are usually found in wall-mounted versions.

Designations

When designating heating devices, it is used letter abbreviation. Each letter contains certain information:

  • K – boiler.
  • G – gas burner equipment is included.
  • T – can be used as solid fuel.
  • C – steel.
  • M – installation of heating elements and an expanded firebox is provided.
  • B – there is a water heater.

Knowing the meanings of the letters, the user can decipher the basic information about the proposed options using the abbreviation.

Model overview

If communications are connected to the housing, you can always provide it with heat and hot water. More than 50% of boilers installed by domestic consumers are gas. Not among them last place ServisGaz products also occupy a position.

KSG-7AT

If you are looking for the most cheap option, pay attention to the non-volatile single-circuit device KSG-7AT. Its estimated cost is 10,600 rubles. Manufacturing material – steel. Floor option Simple and convenient operation. Saves fuel. Capable of heating 80 square meters. Specifications:

  • Maximum power - 7 kW.
  • High efficiency – 85%.
  • Water pressure – 0.1 MPa.

Stable operation even at the lowest pressure in the gas pipeline. Equipped with a gas block. There is a built-in pressure and draft stabilizer. Compact heat exchanger made of steel. Burner material is heat-resistant stainless steel. Convenient to maintain - the lining can be easily removed. Gas connection - on either side. There is a device that collects condensate.

According to users, the model has excellent characteristics. If you replace the burner nozzles, you can use liquefied gas as fuel.

KNG 24

Approximate price 25,000 rubles. Dual-circuit. Wall. Compact device with stylish design. Latest implemented technical advances. Absolutely silent operation - can be installed directly in the room, it will not disturb the residents in any way. The front panel has an LCD screen to display current settings. The boiler can be used for heating rooms equipped with a water heating system and for heating water. Technical specifications:

  • Efficiency – 90%
  • Can heat rooms with a total area of ​​220 square meters.
  • Maximum heating power is 4.6-24 kW.
  • There is automatic ignition.
  • Gas consumption - 2.6 m3/h.

You can connect a heated floor. Closed type combustion chambers. Capable of operating on natural or liquefied gas. There are several stages of automatic protection. Weighs 36 kg.

KSG-11

Purpose – heat supply of premises for various purposes. Design Features:

  • Convenient installation - gas can be connected from any side.
  • Floor.
  • The door can be reinstalled on the user-friendly side.
  • Condensate collection device.
  • Steel heat exchanger.
  • Thermal insulation – 30 mm.
  • Combustion type: low flare.
  • Quiet operation.
  • It is possible to use the EUROSIT 630 or SABC-AT control unit.

Technical specifications:

  • Heating capacity 11 kW.
  • Heating area – 125 sq. m.
  • Efficiency – 90%.
  • Gas consumption – 1.34 m3/h.
  • Weight 48 kg.

KSTG-16

Combined single-circuit boiler with a maximum heating power of 16 kW. Can run on coal or gas. Designed for heating 160 sq. m. Floor installation. Without auto-ignition and flame modulation. Efficiency – 74%.

KSG-10 AT

Floor installation. heating capacity 10 kW. Heats an area up to 100 square meters. m. Fuel consumption - 1.11 m3/h. Price – 11,000 rubles. It is possible, by replacing the burner jets, to burn with liquefied gas - 0.88 kg/h. Consumers note the compactness of the device, its dimensions are 25x47x75 cm. Weight is 48 kg. Tank capacity – 18 liters.

KSG-7 E

Floor. Single-circuit. It features stable operation at low pressure in gas supply pipes. Approximate price – 11,900 rubles. Efficiency 85%. Consumers are attracted by compactness, efficiency and stylish design. Heats up to 80 sq. m. Weighs 37 kg. Open combustion chamber. No auto-ignition. There is no flame modulation. Budget version with a limited set of functions.

Parapet modifications

Their distinguishing feature– absence of a chimney Smoke removal is carried out through a pipe supplied in the kit. Installation – wall. A hole is made in the walls in advance - the chimney pipe is inserted into it. The heater can be mounted on a wall facing the street. Two modifications of the parapet type are available:

  • KSGZ - with one circuit;
  • KSGZV - with two circuits.

The housing is thermally insulated with mineral wool and can be easily removed to access parts of the heater that need cleaning. 89% efficiency. The heat exchanger is protected from salts and scale.

Share