Passport of the geyser VPG 18. Domestic instantaneous water heating devices. Technical characteristics of AGV water heaters

Review of the gas water heater Neva 4511 VPG-18

The household geyser Neva 4511, 4513 (water heater VPG-18) is designed to provide hot water apartments, country houses. This is a compact model with a digital display, reliable and easy to maintain, equipped with a full set of security systems.

Designation of the water heater VPG-18-223-V11-UHL 4.2, where:

IN - water heating apparatus,
P – flow-through;
G – gas;
18 – nominal heating capacity, kW;
223 – the device runs on natural and liquefied gases;
B11 – removal of combustion products through the chimney;
UHL 4.2 – climatic version.

Advantages of the geyser Neva 4511, 4513

Designed to quickly heat water;

Operates at low water pressure (0.10 Bar)

Automatic electronic ignition;

Compact overall dimensions;

Compact 2-tier heat exchanger;

Water-cooled combustion chamber;

Modern security systems;

Built-in temperature indicator;

1-2 water points;

Specifications geyser Neva 4511

Common parameters

Nominal thermal power, kW - 21

Productivity, l/min - 11

Gas pressure (natural/liquefied) - 1.3/2.9 kPa

Nominal gas consumption (natural/liquefied), m3/hour - 2.2/0.8

Minimum water pressure - 30 kPa

Maximum pressure water, kPa - 1000

Type of communication supply - Lower

Diameter of the supply pipe, mm - 19.17

Chimney diameter, mm - 122.6

Control functions of the water heater VPG-18

Control - Mechanical

Functions - Flame adjustment, Water flow adjustment, Auto-ignition

Indication - Display

Indicators - Temperature display

Operating Parameters

Nominal heating capacity - 18 kW.

Efficiency factor - no less than 84%.

Gas group - 2nd; N/3rd; B/P.

Mass flow rate of combustion products of natural / liquefied gas at rated thermal power - 7.4 / 8.0 g/s.

The type of ignition of the device is electronic.

Device dimensions, Dimensions (WxHxD), mm - 290 x 565 x 221 mm

Weight, kg - 10

Geyser Neva 4511, 4513 wall type(see Fig. 1) has rectangular shape, formed by removable lining 4.

On the front side of the cladding there are: water flow adjustment knob 1, gas flow adjustment knob 2, water temperature display 3 and viewing window 5 for monitoring the burner flame. All main elements are mounted on the rear wall 22 (see Fig. 2).

Picture 1. Appearance and dimensions of the geyser Neva 4511, 4513

1 – knob for adjusting water flow; 2 – gas flow adjustment knob; 3 – water temperature display; 4 – facing; 5 – viewing window; 6 – cold water supply fitting, G 1/2 thread; 7 – gas supply fitting, thread G 1/2; 8 – hot water outlet fitting, thread G 1/2; 9 – pipe of the gas exhaust device; 10 – mounting holes.

Figure 2. View of the gas water heater Neva 4511, 4513 without casing

1 – water flow regulator; 2 – gas flow regulator; 3 – plate; 4 – water-gas unit; 5 – burner; 6 – cold water supply fitting; 7 – gas supply fitting; 8 – hot water outlet fitting; 9 – gas exhaust device; 10 – candle; 11 – flame presence sensor; 12 – heat exchanger; 13 – valve
electromagnetic; 14 – battery compartment; 15 – electronic control unit; 16 – thermal relay (draft presence sensor); 17 – microswitch (water flow sensor); 18 – water temperature sensor; 19 – thermal relay (water overheating sensor); 20 – plug for draining water; 21 – fitting for measuring gas pressure; 22 – back wall; 23 – screws for fastening the cladding.

Purpose of main components and components geyser Neva 4511, 4513

Water-gas unit 4 is designed to control the gas supply to the burner, regulate water flow and consists of water and gas units (the design of the unit ensures gas access to the burner only if there is a water flow);

Burner 5 is designed to create and supply an air-gas mixture to the combustion site;

The gas exhaust device 9 is designed to remove combustion products into the chimney;

Spark plug 10 is designed to create a spark discharge to ignite the burner;

The flame presence sensor 11 provides control of the burner operation;

Heat exchanger 12 ensures the transfer of heat obtained from gas combustion to water flowing through its pipes;

Thermal relay 16 (draft presence sensor) is designed to turn off the device if there is no draft in the chimney;

Water temperature sensor 18 is designed to determine the water temperature at the outlet of the apparatus;

Thermal relay 19 (water overheating sensor) is designed to turn off the Neva 4511, 4513 geyser when the water is heated above 90°C;

Plug 20 serves to drain water from the water circuit of the device to prevent it from freezing; The safety valve built into the plug is designed to protect the water circuit of the water heater from increased water pressure.

The working diagram of the VPG-18 water heater is shown in Figure 3.

When water begins to flow through the water unit 22 (see Fig. 3) with a flow rate of at least 2.5 l/min, the membrane rod 25 opens the gas valve 30 and the contacts of the microswitch 17 close, after which the control unit 15 opens the electromagnetic valve 13 and begins to flow high voltage current pulses to spark plug 10.

Burner 5 is ignited by spark discharges between the spark plug electrode and the nozzle of the burner section. Next, the operation of the burner is monitored by flame presence sensor 11.

The water flow regulator 1 regulates the amount and water temperature, leaving the device: turning the regulator counterclockwise increases the flow rate and reduces the water temperature; turning the knob clockwise reduces the flow rate and increases the water temperature.

The position of the regulator also determines the water flow at which the device turns on.

Gas flow regulator 2 regulates the amount of gas entering the burner to obtain the required water temperature at its set flow rate: turning the regulator counterclockwise increases the gas flow and water temperature; turning the knob clockwise reduces gas flow and water temperature.

When water flow stops or its flow rate decreases to less than 2.5 l/min, the contacts of microswitch 17 open and valves 13 and 30 close. The burner goes out.

R Figure 3. Diagram of the gas water heater Neva 4511, 4513

1 – water flow regulator; 2 – gas flow regulator; 3 – water temperature display; 4 – water-gas unit; 5 – burner; 6 – cold water inlet; 7 – gas inlet; 8 – hot water outlet; 9 – gas exhaust device; 10 – candle; 11 – flame presence sensor; 12 – heat exchanger; 13 – electromagnetic valve; 14 – battery compartment; 15 – electronic control unit; 16 – thermal relay (traction sensor); 17 – microswitch; 18 – water temperature sensor; 19 – thermal relay (water overheating sensor); 20 – plug for draining water; 21 – fitting for measuring gas pressure; 22 – water unit; 23 – water purification filter; 24 – water flow limiter; 25 – membrane; 26 – Venturi fitting; 27 – water outlet to the heat exchanger; 28 – gas unit; 29 – gas purification filter; 30 – gas valve; 31 – gas outlet to the burner.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

The NEVA 3208 geyser is convenient, simple and reliable. Despite the venerable age of most of the units in use, they cope with their duties of heating water quite well. But sometimes you want to clarify something in the instruction manual. And this is where the problem arises.

The original instructions are most often lost, and downloading the operating instructions on the Internet is Neva-3208 impossible. More modern columns Neva series 4000, 5000, Neva Lux 6000, boilers Neva Lux series 8000 - please, but there are no instructions for Neva 3208.

The search only turns up fraudulent sites that require a cell phone number, but even there there are no instructions - just a file name. This can be easily checked by trying to find on such a site a file with a obviously non-existent name - for example, “ qwerrasdfgfgh-$%#$@$" He will find it, and even say that it has been downloaded several thousand times! I hope that you don’t fall for such tricks and don’t enter your phone number on suspicious sites. You can find the operating instructions for the Neva-3208 gas water heater here.

HOUSEHOLD FLOW-FLOW GAS WATER HEATING APPARATUS

NEVA-3208 GOST 19910-94

NEVA-3208-02 GOST 19910-94

OPERATION MANUAL 3208-00.000-02 RE

Dear buyer!

When purchasing a device, check the completeness and presentation of the device, and also require the sales organization to fill out warranty repair coupons

Before installing and operating the device, you must carefully read the rules and requirements set out in this operating manual, compliance with which will ensure long-term trouble-free and safe operation of the water heater.

Violation of the installation and operation instructions may lead to an accident or damage the device.

1. GENERAL INSTRUCTIONS

1.1. The instantaneous gas household water heating apparatus "NEVA-3208" (NEVA-3208-02) VPG-18-223-V11-R2 GOST 19910-94, hereinafter referred to as the "apparatus", is intended for heating water used for sanitary purposes (washing dishes , washing, bathing) in apartments, cottages, country houses.

1.2. The device is designed to operate on natural gas in accordance with GOST 5542-87 with a lower calorific value of 35570+/-1780 kJ/m3 (8500+/-425 kcal/m3) or liquefied gas in accordance with GOST 20448-90 with a lower calorific value of 96250+/- 4810 kJ/m3 (23000+/-1150 kcal/m3).

When manufactured at the factory, the device is configured for a specific type of gas, indicated on the plate on the device and in the “Acceptance Certificate” section of this manual.

1.3. Installation, installation, owner instruction, preventive maintenance, troubleshooting and repairs are carried out by gas operating organizations or other organizations licensed for this type of activity. Section 13 must contain a mark and stamp of the organization installing the device.

1.4. Checking and cleaning the chimney, repairs and monitoring of the water supply system are carried out by the owner of the device or the house management.

1.5. The owner is responsible for the safe operation of the device and for maintaining it in proper condition.

2. TECHNICAL DATA

2.1. Rated thermal power 23.2 kW

2.2. Nominal heating output 18.0 kW

2.3. Rated thermal power of the pilot burner no more than 0.35 kW

2.4 Nominal pressure of natural gas 1274 Pa (130 mm water column)

2.5 Nominal pressure of liquefied gas 2940 Pa (300 mm water column)

2.6. Nominal natural gas consumption 2.35 cubic meters. m/hour.

2.6. Nominal consumption of liquefied gas is 0.87 cubic meters. m/hour.

2.7. Efficiency of at least 80%

2.8. Supply water pressure for normal operation of the device 50…600 kPa

2.9. Water consumption when heating by 40 degrees (at rated power) 6.45 l/min

2.10. The temperature of gas combustion products is not less than 110 degrees

2.11. Vacuum in the chimney is not less than 2.0 Pa (0.2 mm water column), not more than 30.0 Pa (3.0 mm water column)

2.12. Ignition of the “NEVA-3208” apparatus is piezoelectric, of the “NEVA-3208-02” apparatus - with a match

2.13. dimensions apparatus: height 680 mm, depth 278 mm, width 390 mm

2.14. Device weight no more than 20 kg

3. DELIVERY SET

3208-00.000 Device “Neva-3208”, or “NEVA-3208-02” 1 pc.

3208-00.000-02 RE Operating manual 1 copy.

3208-06.300 Packing 1 pc.

3208-00.001 Handle 1 pc.

Wall mounting elements 1 set

3103-00.014 Gasket 4 pcs.

3204-00.013 Bushing 1 pc.

4. SAFETY INSTRUCTIONS

4.1. The room where the device is installed must be constantly ventilated.

4.2. To avoid fire, do not place flammable substances or materials on the device or hang it near it.

4.3. After stopping the operation of the device, it is necessary to disconnect it from the gas supply.

4.4. To prevent the appliance from defrosting in winter time(when installed in unheated rooms), it is necessary to drain the water from it.

4.5. To avoid accidents and failure of the device, consumers are PROHIBITED from:

a) independently install and put the device into operation;

b) allow children, as well as persons unfamiliar with this operating manual, to use the device;

c) operate the device on gas that does not correspond to that specified on the plate on the device and the “Acceptance Certificate” of this manual;

d) close the grille or gap at the bottom of the door or wall intended for the flow of air necessary for gas combustion;

e) use the device in the absence of draft in the chimney;

f) use a faulty device;

g) independently disassemble and repair the device;

h) make changes to the design of the device;

i) leave a working device unattended.

4.6. At normal operation device and if the gas pipeline is in good working order, there should be no smell of gas in the room.

If you smell gas in the room, you MUST:

a) immediately turn off the device;

b) close the gas valve located on the gas pipeline in front of the device;

c) thoroughly ventilate the room;

d) call immediately emergency service gas industry by phone. 04.

Until the gas leak is eliminated, do not perform any work related to spark formation: do not light a fire, do not turn on or off electrical appliances and electric lighting, do not smoke.

4.7. If abnormal operation of the device is detected, you must contact the gas service and do not use the device until the malfunction is eliminated.

4.8. If you use a faulty device or if the above operating rules are not followed, an explosion or poisoning may occur with gas or carbon monoxide (carbon monoxide) contained in the products of incomplete combustion of gas.

The first signs of poisoning are: heaviness in the head, palpitations, tinnitus, dizziness, general weakness, then nausea, vomiting, shortness of breath, and impaired motor functions may appear. A person who is burned may suddenly lose consciousness.

To provide first aid, it is necessary to: take the victim into fresh air, unfasten clothing that is restricting breathing, and give him a sniff. ammonia, cover warmly, but do not let you fall asleep and call a doctor.

If there is no breathing, immediately take the victim to a warm room with fresh air and perform artificial respiration without stopping it until the doctor arrives.

5. DEVICE AND OPERATION

5.1. Device structure

5.1.1. The wall-mounted device (Fig. 1) has a rectangular shape formed by a removable lining 7.

5.1.2. All main elements of the device are mounted on the frame. On the front side of the cladding there are: control handle 2 gas tap, button 3 for turning on the solenoid valve, viewing window 8 for observing the flame of the pilot and main burners.

5.1.3. The apparatus (Fig. 2) consists of a combustion chamber 1 (which includes a frame 3, a gas exhaust device 4 and a heat exchanger 2), a water-gas burner unit 5 (consisting of a main burner 6, an ignition burner 7, a gas valve 9, a water regulator 10, a valve electromagnetic 11) and tube 8, designed to turn off the water heater in the absence of draft in the chimney.

NOTE: Due to the fact that OJSC continues to work on further improvement of the device design, the purchased device may not completely match the individual elements with a description or image in the “Operation Manual”.

5.2. Description of the device operation

5.2.1. Gas through pipe 4 (Fig. 1) enters solenoid valve 11 (Fig. 2), the activation button 3 (Fig. 1) is located to the right of the gas tap switch handle.

5.2.2. When you press the solenoid valve button and open” (to the “Ignition” position) (Fig. 3), the gas flows to the pilot burner. The thermocouple, heated by the pilot burner flame, transmits the EMF to the valve electromagnet, which automatically holds the valve plate open and provides gas access to the gas valve.

5.2.3. When turning handle 2 (Fig. 1) clockwise, gas valve 9 (Fig. 2) carries out the sequence of turning on the pilot burner to the “Ignition” position (see Fig. 3), supplying gas to the main burner in the “Apparatus on” position ( see Fig. 3) and regulates the amount of gas supplied to the main burner within the “Big Flame” - “Small Flame” positions (see Fig. 3) to obtain the desired water temperature. In this case, the main burner lights up only when water flows through the device (when the hot water tap is opened).

5.2.4 The device is turned off by turning the control knob counterclockwise until it stops, and the main and ignition burners are instantly extinguished. The valve of the electromagnetic plug will remain open until the thermocouple cools down (10... 15 s).

5.2.5. To ensure smooth ignition of the main burner, the water regulator is equipped with an ignition retarder, which acts as a throttle when water flows out of the above-membrane cavity and slows down the upward movement of the membrane, and therefore the ignition speed of the main burner.

The device is equipped with safety devices that provide:

  • gas access to the main burner only in the presence of a pilot flame and water flow
  • closing the gas valve to the main burner in cases where the pilot burner goes out or the water flow stops,
  • turning off the main and ignition burners in the absence of draft in the chimney.

1 - pipe, 2 - handle; 3 - button: 4 - gas supply pipe; 5 - hot water outlet pipe, 6 - cold water supply pipe; 7 - cladding, 8 - viewing window

Figure 1. Domestic instantaneous gas water heating device

1 - combustion chamber; 2 - heat exchanger; 3 - frame; 4 - gas exhaust device; 5 - water-gas burner block; 6 - main burner; 7 - pilot burner; 8 - draft sensor tube; 9 - gas tap: 10 - water regulator; 11 - solenoid valve; 12 - thermocouple; 13 - piezo ignition (NEVA-3208); 14 - plate.

Figure 2. Domestic instantaneous gas water heating device (without lining)

Figure 3. Gas valve control handle positions

6. INSTALLATION PROCEDURE

6.1. Installation of the device

6.1.1. The device must be installed in kitchens or other non-residential premises in accordance with the Gasification Project and SNiP 2.04.08.87

6.1.2. Installation and installation of the device must be carried out by the operating organization of the gas industry or other organizations licensed for this type of activity

6.1.3. The device is hung with holes (on the frame) on a special bracket mounted on the wall. Mounting holes The device is shown in Figure 4. It is recommended to install the device so that the viewing window 8 (see Figure 1) is at eye level of the consumer.

6.1.4. The connecting dimensions of pipelines for gas supply, water supply and removal, and combustion products removal through the smoke exhaust pipe are shown in Figure 1

6.2. Water and gas connection

6.2.1 Connection should be made with pipes with DN 15 mm. When installing pipelines, it is recommended to first make connections to the water inlet and outlet points, fill the heat exchanger and water system water and only after that make connection to the gas supply point. The connection should not be accompanied by mutual tension of pipes and parts of the apparatus in order to avoid displacement or breakage of individual parts and parts of the apparatus and violation of the tightness of the gas and water systems.

6.2.2. After installing the device, its connections to communications must be checked for leaks. Checking the tightness of the water inlet and outlet connections is carried out by opening the shut-off valve (see Fig. 4) of cold water (with the water taps closed). Leakage at the joints is not allowed.

Check the tightness of the gas supply connection by opening a common tap on the gas pipeline when closed position handles of the device (position "Device off"). The check should be carried out by washing the joints or using special devices. Gas leakage is not allowed.

6.3. Installation of a chimney to remove combustion products

The apparatus must be provided with a system for removing combustion products from the apparatus to the outside of the building. Smoke exhaust pipes must meet the following requirements:

  • must be sealed and made of fireproof and corrosion-resistant materials, such as: stainless steel, galvanized steel, enameled steel, aluminum, copper with a wall thickness of at least 0.5 mm;
  • the length of the connecting pipe should not be more than 3 m, there should be no more than three turns on the pipe, the slope of the horizontal section of the pipe should be at least 0.01 towards the water heater;
  • the height of the vertical part of the pipe (from the water heater to the axis of the horizontal section) must be at least three times the diameter;
  • the internal diameter of smoke exhaust pipes must be at least 125 mm.

6.3.3. The connection between the device and the chimney must be sealed. It is recommended to install the pipe according to the diagram in Figure 5.

6.4. After installation, installation and leak testing, the operation of the safety automatics must be checked (clauses 5.2.5 and 5.2.6.).

Figure 4. Device installation diagram

1 - smoke exhaust pipe; 2 - pipe; 3 - heat-resistant seal

Figure 5. Connection diagram for the smoke exhaust pipe

7. OPERATION PROCEDURE

7.1. Turning on the device

7.1.1. To turn on the device it is necessary (see Fig. 4)

a) open the common valve on the gas pipeline in front of the device;

b) open the cold water shut-off valve (in front of the device);

c) set the handle of the device to the “Ignition” position (see Fig. 3),

d) press the solenoid valve button 3 (see Fig. 1) and repeatedly press the piezo ignition button 13 (see Fig. 2) (or bring a lit match to the pilot burner) until a flame appears on the pilot burner;

e) release the solenoid valve button after turning it on (after no more than 60 s), while the pilot burner flame should not go out.

WARNING: To avoid burns, do not place your eyes too close to the viewing window.

When igniting for the first time or after a long period of non-use of the device, in order to remove air from gas communications, repeat the specified operations in items d and e.

e) open the gas tap to the main burner, to do this, turn the gas tap handle to the right until it stops (the “Big Flame” position). In this case, the pilot burner continues to burn, but the main burner has not yet ignited.

g) open the water tap, and the main burner should ignite. The degree of water heating is adjusted by turning the handle of the device within the “Large Flame” - “Small Flame” positions or by changing the flow rate of water passing through the device.

7.2. Turning off the device

7.2.1. At the end of use, you must turn off the device, observing the following sequence:

a) close the water taps (see Fig. 4);

b) turn knob 2 (see Fig. 1) to the “Device off” position (counterclockwise until it stops);

c) close the common tap on the gas pipeline;

d) close the cold water shut-off valve.

8. MAINTENANCE

8.1. To ensure long-term trouble-free operation and maintain the performance of the device, it is necessary to regularly carry out care, inspection and maintenance. Maintenance and inspection are carried out by the owner of the device.

Maintenance is carried out at least once a year by gas service specialists or other organizations licensed for this type of activity.

8.2.1. The device should be kept clean, for which it is necessary to regularly remove dust from the top surface of the device, and also wipe the lining first with a damp and then with a dry cloth. In case of significant contamination, first wipe the lining with a wet cloth moistened with a neutral detergent, and then with a dry cloth.

8.2.2. It is prohibited to use detergents enhanced action and containing abrasive particles, gasoline or other organic solvents for cleaning the surface of the cladding and plastic parts.

8.3. Inspection

Before each time you turn on the device, you must:

a) check that there are no combustible objects near the device;

b) check for gas leaks (by characteristic odor) and water leaks (visually);

c) check the serviceability of the burners according to the combustion pattern:

the pilot burner flame must be elongated, not smoking, and reach the main burner (deflection of the flame sharply upward indicates clogging of the air supply channels to the burner);

the flame of the main burner should be blue, smooth and free of yellow smoking tongues, indicating contamination of the outer surfaces of the nozzles and inlet openings of the burner sections.

In cases where gas and water leaks are detected, as well as burner malfunctions, it is necessary to repair and maintain the device.

8.4. Maintenance

8.4.1. During maintenance the following work is performed:

  • cleaning and flushing the heat exchanger from scale inside the pipes and from soot outside;
  • cleaning and washing water and gas filters;
  • cleaning and flushing of the main and ignition burners;
  • cleaning and lubricating the conical surface of the plug and the opening of the gas valve;
  • cleaning and lubrication of seals and rods of water and gas blocks;
  • checking the tightness of the gas and water systems of the device;
  • checking the operation of the safety automation, including the draft sensor, for which it is necessary to remove the smoke exhaust pipe (see Fig. 1), turn on the device and, with the gas valve fully open and maximum water flow, close the device pipe metal sheet. After 10...60 seconds the device should turn off. After checking, install the smoke exhaust pipe according to Figure 5.

Works related to technical maintenance, are not warranty obligations of the manufacturer.

9. POSSIBLE MALFUNCTIONS OF THE NEVA 3208 APPARATUS AND METHODS OF THEIR ELIMINATION

Fault name

Probable Cause

Elimination methods

The igniter is difficult to ignite or does not ignite at all.

Presence of air in gas lines.

See paragraph 7.1 Turning on the device

Igniter nozzle clogged

Replace the liquefied gas cylinder

When the solenoid valve button is released (after a control time of 60 s), the igniter goes out.

The pilot burner flame does not heat the thermocouple

Call the gas service

The electrical circuit thermocouple - solenoid valve is broken

Check the contact of the thermocouple with the solenoid valve (clean the contacts if necessary)

Check the tightness of the connection between the thermocouple and the solenoid valve, remembering: the tightening force must ensure reliable contact, but should not exceed 1.5 N-m (0.15 kg-m) to avoid failure of these components.

The electromagnetic plug or thermocouple has failed

Call the gas service

The main burner does not ignite or is difficult to ignite when opening the hot water tap.

Insufficient opening of the gas valve on the device or the general valve on the gas pipeline

Turn the handle of the device to the “Big Flame” position and fully open the general valve on the gas pipeline

Low gas pressure

Call the gas service

Low tap water pressure

Stop using the device temporarily

The water filter is clogged, the membrane is torn or the water block plate is broken

Call the gas service

The main burner does not go out when the hot water tap is closed

Gas or water block rod jammed

Call the gas service

The flame of the main burner is sluggish, elongated, with yellow smoky tongues

Dust deposits on the nozzles and internal surfaces main burner

Call the gas service

After a short period of operation, the device turns off spontaneously

No draft in the chimney

Clean the chimney.

The supply of liquefied gas in the cylinder has run out

Replace the liquefied gas cylinder.

The handle of the faucet plug turns with considerable force

Grease drying out

Call the gas service

Ingress of contaminants

Call the gas service

Low water flow at the outlet of the device with normal water pressure in the pipeline

Presence of scale in the heat exchanger or in the hot water outlet pipe

Call the gas service

Insufficient water heating

High water consumption

Deposition of soot on the fins of the heat exchanger or scale in the heat exchanger pipes

Call the gas service

When the device is operating, there is increased noise from flowing water.

High water consumption

Adjust the water flow to 6.45 l/min.

Misalignment of gaskets in the water block connection

Correct misalignment or replace gaskets.

The main burner ignites with a “pop” and the flame shoots out of the casing window

The ignition burner flame is small or deviates sharply upward and does not reach the main burner (the nozzle is clogged or the air supply channel to the igniter is clogged with dust, the groove on the valve plug is partially clogged with grease, low gas pressure)

Call the gas service

Ignition retarder does not work

Call the gas service

The igniter does not ignite with piezo ignition (it ignites normally with a match)

There is no spark between the spark plug and the igniter

Check the connection of the piezoelectric generator wires to the spark plug and to the body of the device.

There is a weak spark between the spark plug and the igniter

Establish a gap of 5 mm between the spark plug electrode and the igniter.

10. STORAGE RULES

10.1. The device must be stored and transported only in the position indicated on the handling signs

10.2. The device must be stored in indoors, guaranteeing protection from atmospheric and other harmful effects at air temperatures from -50°С to +40°С and relative humidity not exceeding 98%.

10.3. If the device is stored for more than 12 months, it must be preserved in accordance with GOST 9.014

10.4. The openings of the inlet and outlet pipes must be closed with plugs or plugs.

10.5. After every 6 months of storage, the device must undergo a technical inspection, during which it is checked that there is no ingress of moisture and dust contamination of the units and parts of the device.

10.6. The devices should be stacked in no more than five tiers when stacked and transported.

11. CERTIFICATE OF ACCEPTANCE

Household instantaneous gas water heating device. NEVA - 3208 complies with GOST 19910-94 and is recognized as suitable for use

12. WARRANTY

The manufacturer guarantees trouble-free operation of the device if there is project documentation for installation of the device and subject to the consumer’s compliance with the rules of storage, installation and operation established by this “Operation Manual”.

The warranty period for the device is 3 years from the date of sale through a retail network; 3 years from the date of receipt by the consumer (for off-market consumption);

12.3. Warranty repair the device is produced by gas services, the manufacturer or other organizations licensed for this type of activity.

12.4. The average service life of the device is at least 12 years.

12.5. When purchasing a device, the buyer must receive an “Operation Manual” with the store’s mark of purchase and check that it contains tear-off coupons for warranty repairs.

12.6. If the warranty cards do not contain a store stamp indicating the date of sale of the device, the warranty period is calculated from the date of its release by the manufacturer.

12.7. When repairing the device, the warranty card and its counterfoil are filled out by an employee of the gas industry or an organization licensed for this type of activity. The warranty card is confiscated by an employee of the gas industry or an organization licensed for this type of activity. The warranty card stub remains in the instruction manual.

12.8. The Manufacturer is not responsible for the malfunction of the device and does not guarantee its operation if the Consumer’s claim provides evidence of:

a) failure to comply with installation and operation rules;

b) failure to comply with the rules of transportation and storage by the Consumer, trading and transport organizations;

Evidence can be presented either in the form of an independent Expert’s conclusion or in the form of an act drawn up by a representative of the Manufacturer and signed by the Consumer.

To heat water used for domestic purposes and in water heating systems, various water heaters are used: VPG-18-A, AGV-80 and AGV-120.

Flow-through gas water heater VPG-18-A, designed for continuous heating of running water, can be used for multi-point water supply. The water heater runs on natural and liquefied gases.

The VPG-18-A water heater is made in the shape of a parallelepiped, the outer surfaces of which are covered with white enamel. The main elements of the apparatus are the main and ignition burner, heat exchanger, gas burner unit, solenoid valve, thermoelectric thermometer, draft measuring transducer and piezoelectric ignition device. All elements of the device are mounted in a detachable casing, thanks to which you can freely inspect and repair its elements without removing the device from the wall.

On the front wall of the device there is a control handle for the gas tap, buttons for turning on the solenoid valve and the piezoelectric ignition device. In the upper part of the device there is a device for discharging combustion products into the chimney, in the lower part there are pipes for connection to the water supply system and gas pipeline. Automatic devices ensure that the gas supply to the main burner is stopped if water does not flow to the device, if there is no draft in the chimney and if the pilot burner flame goes out.

Technical characteristics of the water heater VPG-18-A

VPG-18-A water heaters are installed in kitchens or bathrooms and secured using hooks or screws screwed into dowels embedded in a fireproof wall. If the water heater is mounted on a wooden plastered wall, then a 3 mm thick sheet of asbestos roofing steel is nailed to it behind the water heater.

Gas water heaters are installed at a distance of 970-1200 mm from the bottom of the housing to the floor. Water heaters are connected to the chimney by roofing steel pipes. The diameter of the pipe must be no less than the diameter of the pipe on the drainage device flue gases. The length of the vertical section of pipes above the draft breaker must be at least 0.5 m, and the horizontal section no more than 3 m in new houses and 6 m in previously built ones. The slope of the pipes is 0.01 towards the water heater.

The pipes are tightly pushed into one another along the gas flow by at least 0.5 D) (where D is the diameter of the pipe) and they must have no more than three turns with a radius of curvature of at least D. At a distance of 10 cm from the end of the pipe, a washer is installed that rests into the wall.

The water heater is installed like this: the installation location is marked, holes are marked and punched for dowels, which are embedded in the wall. Then they wrap it in dowel screws, hang the water heater and connect it to the gas and water connections.

Automatic gas water heaters AGV type are capacitive water heaters used for hot water supply systems and providing multi-point water supply. Such water heaters are installed in bathrooms, kitchens or rooms with a volume of at least 6 m 3 with a mandatory connection to a separate flue. Automatic gas water heaters AGV-80 and AGV-120 consist of the following main elements: a galvanized welded tank, a combustion chamber with a burner, a thermostat, a magnetic gas valve, an ignition burner, a thermoelectric thermometer, a safety valve and a draft breaker.

Casing 1 of the AVG-80 water heater (Fig. 244) is a cylinder made of sheet steel 1 mm thick and painted with enamel paint. Between the walls of the tank and the casing there is a 2¦ thermal insulation layer of slag wool.

Rice. 244. Automatic gas water heater AGV-80:
1 - casing, 2 - thermal insulation, 3 - water tank, 4 - cold water pipeline. 5 - flame tube, 6 - gas flow extension, 7 - drain fitting, 8 - tonka, 9 - gas burner, 10 - air supply regulator, 11 - firebox door, 12 - thermocouple, 13 - temperature regulator sensing element, 14 - tube igniter, 15 - thermocouple tube, 16 - burner tube, 17 - temperature control valve, 18 - button, 19 - solenoid valve, 20 - gas valve, 21 - plug valve, 22 - gas pipeline, 23 - hot water pipe, 24 - traction breaker

The cylinder tank with upper and lower bottoms is made of galvanized steel 3 mm thick. In the upper bottom there are two fittings with a diameter of 20 mm, one of them is used to connect pipelines 4 for cold water, the other 23 is for drawing hot water.

Water drains from the water heater through fitting 7.

Along the axis of the tank there is a flame tube 5 with a diameter of 80 mm, through which hot gases pass from the combustion chamber and heat the water. To increase heat transfer, a gas flow extension 6 is placed inside the flame tube. A draft breaker 24 is placed on top of the pipe. 8 In the firebox 8 of the water heater there is a gas burner 9 low pressure injection type. On the gas pipeline 22, as well as in front of the burner and igniter, plug valves 21 and gas valves 20 are installed. To maintain a constant water temperature, a sensitive element 13 of the thermostat is installed in the middle part of the water heater tank.

Gas enters the burner through solenoid valve 19, which is turned on when button 18 is pressed, and thermostat valve 17. Near the igniter tube 14 there is a thermoelectric thermometer tube 15 and a thermoelectric thermometer 12 with a bimetallic plate that regulates the passage of gas to the burner.

The water heater tank is constantly under pressure from the water supply. The ignition field of the burner is heat from its flame and hot gases passing through the flame tube heat the water.

When the water in the tank is heated to a predetermined temperature, the brass tube of the regulator's sensitive element lengthens and pulls back the rod of the regulator lever connected to it. The regulator levers are moved by a lever spring to another position and release the regulator valve. The valve closes under the action of its spring and the flow of gas through the regulator to the burner stops. The flame in the burner goes out, but the igniter burns because gas is supplied to it through the solenoid valve.

When the water in the tank cools below the set temperature, the regulator tube, cooling, shortens and presses the rod on the regulator lever. The regulator levers are moved by a lever spring to their original position and open the regulator valve. The gas flows through the solenoid valve and the regulator valve to the burner and is ignited by the igniter. If the igniter goes out, the thermoelectric thermometer will cool, the electric current in the circuit will disappear, the solenoid valve will close and stop gas access to the burner and igniter. To regulate the amount of air supplied to the burner 9, an air supply regulator 10 is used.

The device is also equipped with automatic draft and flame control, which stops the gas supply if there is no draft from the chimney or the pilot burner flame goes out.

Technical characteristics of AGV water heaters

When installing residential heating and hot water supply from the AGV-80 water heater (Fig. 245), the cold water pipeline is connected to the water heater through the lower drain fitting. On the water supply line they put check valve and valve and arrange a branch with a valve to drain water from the system. Hot water is directed through the upper fitting and riser into the expansion vessel, from which the upper hot line of the heating system is laid. The hot riser is insulated. To increase circulation pressure, it is recommended to install radiators at a height of 30-35 cm from the bottom of the device to the floor.

Rice. 245. Scheme of apartment heating and hot water supply from the gas water heater AGV-80:
1 - pipe to the chimney, 2 - safety line from the valve, 3 - pipeline to the heating system, 4 - pipeline from the heating system

The return line is connected to the lower drain fitting after the check valve. A drain pipe is led from the expansion vessel to the sink. A safety valve is installed on the hot riser, from which a pipe is laid to the washbasin or sink. Hot water is supplied to sanitary fixtures, as shown in the figure. For ease of ignition of the igniter and maintenance of the water heater, it is installed on a stand. When installing the water heater on a wooden floor, place it underneath steel sheet on asbestos cardboard.

For heating separate rooms with an area of ​​30 to 150 m2, heating devices AOG-5, AOGV-20, respectively, operating on natural and liquefied gas are used. The devices are made in the form of a rectangular cabinet (Fig. 246), the front surfaces of which are covered with white silicate enamel. The main elements of the apparatus are the combustion chamber, heat exchanger, burners (one or two), automatic device combustion safety, which provides control of the presence of a flame on the ignition burner and draft in the chimney and an automatic device for regulating the water heating temperature, which maintains its heating temperature within specified limits and, when the maximum is reached, turns off the gas supply to the main burner.

Rice. 246. Heating apparatus

Technical characteristics of heating devices

Despite the fact that today housing and communal services networks are being modernized everywhere, the quality of the services they provide remains at a low level. This is especially true for hot water supply. To solve this problem once and for all, you should purchase gas water heater. However, you first need to decide which model is best for you.

Modern manufacturers offer the mentioned devices in a wide range. They have certain operational and technical characteristics. Columns can be classified into flow-through and storage. As for the first ones, they are smaller in size, which allows them to be installed even in small room. Storage gas water heaters can hold from 50 to 500 liters of water.

The capacity in the design has effective thermal insulation, which allows you to save high temperature water for a long time, this helps to save energy resources. If you still can't decide which geyser choose, then you can pay attention to equipment under the Astra brand, which will be discussed below. Such devices are good not only because they are manufactured in Russia, which means they have an acceptable cost, but also because they are maintainable. This indicates that in the event of a malfunction, you can figure it out yourself.

Reviews of Astra brand geysers

If you want to save twice as much, you should purchase a water heater domestic production. These are precisely the Astra geysers. Consumers choose them for their affordable price, but this advantage cannot be called the only one. The units operate on liquefied and natural gas. Buyers also like high level safety, which the manufacturer took care of. After all, if the pilot burner goes out, the supply of water for heating will stop, this also applies to the automatic supply of gas.

Such water heaters act as optimal solution For household use. Buyers also like the ease of operation and maintenance. You won't have to spend money on this. The appearance of the design is attractive, the body has a modern and stylish design. Any geyser from the manufacturer can fit into the interior of the room. Astra geysers, according to buyers, are offered for sale in a wide range. That's why you can choose the most best option, which will meet the requirements and preferences of the consumer.

Technical characteristics of VPG 8910-00.02

If you are interested in Astra geysers, then you should consider several models at once so that you have the opportunity to make right choice. Among others, the VPG 8910-00.02 model, which is manufactured in Russia, is presented on the market. Its power can reach 21 kW. The design is equipped open camera combustion and manual ignition.

The hot water supply capacity is 12 l/min. The supplied water can have a temperature that varies from 35 to 60 °C. During operation, the column consumes natural gas in a volume equal to 2.3 m 3 /h. The maximum water pressure can be 6 bar. Minimum working water pressure equivalent to 0.5 bar.

Gas connection is carried out using communications that have the following parameters: 3/4 inch. Hot and cold water connections are made using pipes with a diameter of 1/2 inch. The chimney diameter reaches 120 mm. If you are considering Astra geysers, then you should definitely be interested in their dimensions. As for the model described in the section, its dimensions are 700x372x230 mm. The equipment weighs 15 kg.

Technical characteristics of the column brand VPG 8910-08.02

In order to make the right choice, you need to consider several models. Among others, the VPG 8910-08.02 variant is presented on the market, the power of which reaches 18 kW. The design has an open combustion chamber and manual view ignition The productivity of this model is slightly less and is 10 l/min. The temperature of the supplied water remains at the same level, but the fuel consumption will be slightly lower and amount to 2 m 3 / h. Minimum and maximum operating pressure the waters remain the same. The connection is made with the same parameters. The diameter of the chimney remains the same. The design body has identical parameters.

Technical characteristics of the geyser brand VPG 8910-15

This geyser "Astra 8910" has a power of 18 kW. Electric ignition is carried out from batteries. Water capacity is 10 l/min. Natural gas consumption is 2 m 3 /h. The diameter of the chimney in this case is slightly different, it is equivalent to 135 mm. This product comes with a two-year warranty.

Technical characteristics of the geyser brand VPG 8910-16

The power of this equipment reaches 21 kW. Electric ignition is carried out from batteries. The hot water output is slightly higher, it is 12 l/min. Natural gas consumption remains the same as the first of the models described above, this parameter reaches 2.3 m 3 / h. The chimney diameter is 135 mm. The equipment weighs 15 kg.

Why should you choose Astra geysers: reviews

Among the main advantages of the equipment described in the article, consumers highlight:

  • lack of unnecessary functionality;
  • reliability;
  • the ability to easily configure the operation of the equipment;
  • high productivity;
  • simple device;
  • ease of use.

The equipment, according to consumers, is repairable. All spare parts can be found in service workshops. And the column itself is quite cheap. Buyers especially like large combustion chambers, so the power of some models reaches 20 kW.

The traction control of the 8910 model is carried out independently. Thermostat in this option located below. The smoke exhaust path is quite wide, but the column regulator is located under the central fitting. The frame of the structure, according to property owners who purchased such equipment for themselves, is very durable, so it can withstand any load.

The power supply has a protection system. Using special screws, you can easily adjust the fitting. The Astra geyser, the operating instructions for which is supplied, has, according to consumers, economical consumption fuel. The design has a high-quality pressure regulator. Traction can be checked very simply. Removal of combustion products occurs quickly. In terms of safety, the speaker outperforms other models.

Repair of Astra brand geyser

Repair of the Astra geyser begins with shutting off the gas. The column does not need to be removed. The front part can be dismantled using a screwdriver, but first you need to unscrew the bolts located on the sides. The first thing you need to check is the economizer; it is located behind the electrode. Removing the latter will be quite difficult. It is fixed with 4 bolts. You should not touch the heat exchanger.

When you repair individual components, it is important not to touch the fitting; it is used to measure pressure. If this part is damaged, the head will have to be replaced. In order to remove the economizer, you only need to unscrew the two side bolts. The consumer may well carry out the repairs with his own hands. The Astra geyser has contacts in its design that often become dirty. If they become unusable, they need to be replaced. If the economizer does not work after replacement, then it will also have to be changed. These faults are among the main ones for Astra speakers.

If you are faced with a problem when the Astra gas water heater does not light up, this may indicate a lack of draft in the ventilation passage. You can check the traction very simply. The gas water heater is turned off, and a burning match should be brought to the chimney outlet. If the flame is carried into the chimney, then everything is in order - you can connect the column. Otherwise, the chimney should be cleaned. However, it is better to entrust this matter to a special master.

The Astra geyser, the malfunctions of which you should consider when operating this equipment, sometimes goes out immediately after ignition. In this case, you should adjust the supply of cold water to the column. You should not try to dilute hot and cold water, this may cause the flame to go out.

Spare parts for Astra brand gas water heater

If you purchased an Astra 8910 geyser, you may need spare parts for it during operation. You need to know what their cost is. For example, a water unit will cost 1,600 rubles. The gas part costs 1,500 rubles. The magnetic plug has more low price- 205 rub. The membrane costs 25 rubles. The repair kit for the water part costs 155 rubles, and the adjustment unit costs 55 rubles.

Conclusion

If you still don’t know whether it’s worth purchasing an Astra brand geyser, then you should consider its features in more detail. For example, copper heat exchanger All models have increased wall thickness. This provides good heat transfer from heated gases to water, which allows you to save. For more convenient operation, the manufacturer has equipped the design with a display with which you can determine the temperature of the heated water.